Collapse AllExpand All

2.12.17. Resetting the Parameters to Default Values Previous topic Parent topic Child topic Next topic

If the parameters of one or all branches of the NCUI2/4 data are to be reset to default values, e.g. after being changed temporarily for diagnostic work, this can be performed in the INITNCU2 branch. The example sets all ASC parameters to their default values.
assistant-2.gif
Initialization can only be initiated in expert mode.
Expert Mode > OpenScape 4000 > Expert Access > Open ...<IP> with AMO (see AMO command)
comwin-2.gif
CHANGE-STMIB:MTYPE=INITNCU2,LTU=17,TYPE=ASC;
The changes under TYPE ASC, DSP, H323, JB, SNMP, MGNTDATA, WBMDATA and DLSDATA become effective immediately without interrupting operation.
Changes under TYPE GLOBAL, IFDATA, SERVIF, DMCDATA and SIGQOS become effective after the access point has been restarted.
This behaviour is also valid for the command CHANGE-STMIB:MTYPE=INITNCU2,LTU=17, TYPE=ALL;. Therefore it is recommended to restart the access point after resetting all parameters.
assistant-2.gif
Configuration Management > System Data > IPDA > IPDA System Data
Click Search and select the access point. Click Execute on the Action pull-down menu and select the mode of action Update AP, confirm with OK.
comwin-2.gif
EXEC-USSU:MODE=UPDATAP,LTU=17;
IMPORTANT:
Connections are cleared down without further warning. Prior to the EXEC-USSU:UPDATAP, the configuration must be updated on the system hard disk.