Collapse AllExpand All

2.14.4. TYPE DMCDATA - Changing the HG 3500 Setting to Support Direct Media Connections Previous topic Parent topic Child topic Next topic

Use this parameter to set the number of simultaneous direct media connections permitted on a certain HG 3500. The connections are counted both in the OpenScape 4000 central system’s software and on the board itself.
assistant-2.gif
Configuration Management > System Data > Board > Board
Click Search and select STMI.
Make the settings on the STMI Board Data tab under Number of DMC connections and Save.
Configuration Management > System Data > Maintenance > Board Maintenance
Click Search and select STMI.
Click Execute on the Action pull-down menu, select Restart and confirm with OK.
comwin-2.gif
CHANGE-CGWB:MTYPE=CGW,LTU=5,SLOT=91,TYPE=DMCDATA,DMCCONN=30; This change does not become effective on the HG 3500 until this board is restarted with RESTART-BSSU:ADDRTYPE=PEN,LTU=5,SLOT=91.
IMPORTANT:
Existing links are disconnected.