Configuration Management > System Data > Board > CGW
Function Block
Click New, enter data and click Save.
Configuration Management > System Data > Board >
Board
Click New, enter data (header information, General
Board Data tab, STMI2-IGW Board Data tab, CGW
Functionalities tab) and Save.
|
|
|
ADD-BFDAT:FCTBLK=1,FUNCTION=SIP,BRDBCHL=BCHL60; CHANGE-BFDAT:CONFIG=CONT,FCTBLK=1,FUNCTION=SIP,LINECNT=10,BCHLCNT=10; CHANGE-BFDAT:CONFIG=OK,FCTBLK=1,ANSW=YES; ADD-BCSU:MTYPE=IPGW,LTG=1,LTU=1,SLOT=49,PARTNO=”Q2316-X “,FCTID=1,FCT BLK=1; ADD-CGWB:LTU=1,SLOT=49,SMODE=NORMAL,IPADR=1.40.41.105,NET MASK=255.255.255.0,DEFRT=1.40.41.254; The Parameter GWAUTREQ and SIPREG must be set to
NO,in situations where the board is used for SIP Subscriber.
CHANGE-CGWB:MTYPE=CGW,LTG=1,LTU=1,SLOT=49,TYPE=SIPTRERH,GWAUTREQ=NO; CHANGE-CGWB:MTYPE=CGW,LTG=1,LTU=1,SLOT=49,TYPE=SIPTRSSA,SIPREG=NO; |