11.2.9. Configuring the Display for AP Emergency on the Terminal Previous topic Parent topic Child topic Next topic

If an access point/OpenScape 4000 SoftGate is actively controlled by a survivability unit, i.e. a CC-AP/Survivable OpenScape 4000 SoftGate, there are changes that the user needs to know about.
This information is output on the second line of the terminals’ idle display. The text to be output must be agreed upon with the customer.
The output text replaces the LOGO information that can be output during normal operation.
The maximum text length is 22 characters and may comprise numbers and letters in upper and lower case.
IMPORTANT:
Insert blank spaces for all positions in the second display line where information is output in idle mode, and leave enough room to allow the information to be read. For example, if the telephone’s number is shown in the first 5 spaces of the idle display, you must start the AP Emergency information text with at least 6 blank spaces.
Use the AMO ZANDE for this setting.
assistant-2.gif
You must be in expert mode to make this setting with the AMO ZANDE.
Expert Mode > Expert Access > Open ...<IP> with AMO (see AMO command)
comwin-2.gif
CHANGE-ZANDE:TYPE=ALLDATA,APEDTXT=“      Emergency operation “;
The text should be exactly 22 characters long.
The modified data does not take effect until after you have used OpenScape 4000 Assistant Backup & Restore to copy the database to the CC-AP/Survivable OpenScape 4000 SoftGate, and the CC-AP/Survivable OpenScape 4000 SoftGate has accepted it.