7.3.3. Activating the Large Enterprise Gatekeeper Previous topic Parent topic Child topic Next topic

This step is only necessary if you do not want to run a Large Enterprise Gatekeeper for least cost routing on the local OpenScape 4000 system. The feature is active by default.
If you do not want a gatekeeper at the local OpenScape 4000 system, then the feature must be deactivated in the system before HG 3500 is installed. The GATEKPR parameter in the AMO ZANDE is used for this.
IMPORTANT:
You cannot enable or disable the gatekeeper function at an OpenScape 4000 system by simply activating or deactivating the AMO ZANDE once HG 3500 generation is complete. Instead, you must remove all STMI2/4 and STMIX/STMIY HG 3500 boards, activate/deactivate the ZANDE parameter, and finally reinstall the boards. This sequence is necessitated by the different configurations of feature-specific data.

Generation

AMO ZANDE
The AMO ZANDE is used on every OpenScape 4000 system to specify whether or not this feature should be used.
assistant-2.gif
Configuration with the AMO ZANDE can only be executed in expert mode.
Expert Mode > Expert Access > Open ...<IP> with AMO (see AMO command)
comwin-2.gif
ADD-ZANDE:TYPE=ALLDATA,GATEKPR=YES;
This command specifies that the LEGK address resolution function (AMO GKREG) should be operated and administered at the local OpenScape 4000 system.

Table 18. AMO ZANDE parameters in the CHANGE branch under TYPE=ALLDATA

AMO
Parameter
Sprache/ Language
Beschreibung/ Description
ZANDE
GATEKPR
d
Gatekeeper Konfigurierung
Diese Parameter muss auf NEIN gesetzt werden wenn eine PBX ohne Gatekeeper betrieben werden soll. Standardmäßig wird JA, d.h. also ein Gatekeeper wird an der lokalen PBX betrieben, eingerichtet.
 
GATEKPT
e
Gatekeeper configuration
This Parameter must be set to NO when a PBX has to operate with-out a gatekeeper. Default value is YES, that means a gatekeeper will be configured on the local PBX.

Display

assistant-2.gif
Displaying with the AMO ZANDE can only be executed in expert mode.
Expert Mode > Expert Access > Open ...<IP> with AMO
(see AMO command)
comwin-2.gif
DISPLAY-ZANDE:TYPE=ALLDATA;
Use this command to output all central parameters in the ALLDATA branch, including the gatekeeper parameter.