Collapse AllExpand All

11.6.1. Survivability Unit for AP Emergency Previous topic Parent topic Child topic Next topic

The survivability unit integrates a control processor in an access point. A maximum of 83 survivability units can be integrated in the system with the maximum 83 access points per system.
The survivability unit processor requires 2 LAN connections in the IP network.
Detailed information can be found in “Section 2 - System Components (Harwdare & Software) > OpenScape 4000 in the Customer LAN > AP 3700 IP/OpenScape 4000 SoftGate with Survivability Unit in the Customer LAN”.
An “IPDA“ interface is required for the signaling connection with the allocated access points.
PHY
10/100 Base T - autosensing or can be permanently set
MAC address
Permanently programmed ->sticker
(the higher of the two addresses)
IP address
Configured in the OpenScape 4000 system, can be set
IEEE 802.1 p/q VLAN tagging
Configurable; priority bits are always set when active. See Table 3 “TOS values” in document “Gateways HG 3500 and HG 3575”.
The VLAN ID can be set. Configuration in the OpenScape 4000 system.
TOS/DiffServ
The six highest bits in the TOS byte can be set. See Table 3 “TOS values” in document “Gateways HG 3500 and HG 3575”. Configuration in the OpenScape 4000 system.
Protocols/ports
See Chapter 20, “IP Ports” in the document “Gateways HG 3500 and HG 3575”.
Routing
The default host route, which is configured for HG 3575 in the same shelf, is used for the access point.
Firewall
The central processor only allows connections to addresses that it knows, i.e. access points or assigned service PCs.
Number of connections
Up to 83 TCP/IP connections (one per allocated access point)
An additional “CUSTOMER“ interface is required for remote access by OpenScape 4000 Manager and for accessing the file server, which distributes OpenScape 4000 central system software and data.
PHY
10/100 Base T - autosensing
MAC address
Permanently programmed on the board, ->sticker
(lower of the two addresses)
IP address
Can be configured in the OpenScape 4000 Assistant
Routing
Configurable
Number of connections
TCP/IP connection to file server if required.
Administration via OpenScape 4000 Assistant
Security
The same as for OpenScape 4000 Assisatnt