The display of a subscriber in idle state (with no active call) does
not indicate if the station is secure or not.
Display via key
You can configure a key in AMO TAPRO to display the status of the
station:
Example: CHANGE-TAPRO:STNO=<station number>,KY09=SECURE;
Please note that the first eight keys are preprogrammed in OpenStage
subscribers.
Display via SPE entry in menu
You can also check the security status of the subscribers in idle
call state using the subscribers menu.
- Voice encryption not enabled
- The subscriber is connected to the switch via TLS but SPE is not activated
for this subscribers or
- The subscriber is connected to the switch via TCP. In this case subscribers
configuration at the switch is not relevant.
In this case encryption is always disabled (Voice encryption not enabled).
- Voice encryption enabled
-
The subscriber is connected to the switch via TLS and the subscriber
is configured as a SECURE client.
In this case encryption is enabled (Voice encryption enabled).
- Voice encryption always active
-
The subscriber is connected to the switch via TLS and the subscriber
is configured as a CIPHER client.
- Logon via TCP not possible.
- All media streams are encrypted (at least to the gateway).
In this case encryption is always active (Voice encryption always active).