Collapse AllExpand All

18.7.1. OpenScape 4000 Previous topic Parent topic Child topic Next topic

Requirements for SPE

IMPORTANT:
SPE certificates can be configured at the gateways even if SPE is deactivated.
  1. An NTP server must be configured for time synchronization.
  2. The following must be set in AMO ZANDE SPESUPP=YES: CHANGE-ZANDE:TYPE=SECURITY,SPESUPP=YES; In case AP shelves or SoftGate are configured also following command should be executed: CHANGE-SIPCO:TYPE=SECURITY,IPDAENCR=Y;
  3. In case of duplex configuration, the standby node should be restarted as well:
EX-REST:TYPE=UNIT,UNIT=BPS,RSLEVEL=HARD; EX-REST:TYPE=UNIT,UNIT=BP,RSLEVEL=HARD;
  1. Following subscriber settings must be verified: The parameter CLASSEC=SECURE must be set in AMO SDAT for each SPE subscriber:
CHANGE-SDAT:TYPE=DATA1,CLASSEC=SECURE;
  1. You have to check in AMO CGWB for HFA stations if the value in the parameter branch TYP=GLOBIF is TLSP=4061.