27.2.5
REGENERIEREN-BCSU
Aus programmtechnischen Gründen werden eingerichtete Basisstationen vor den eigentlichen Baugruppen regeneriert.
Prozedurübersicht
Kommandocode
Parameter
REGENERIEREN-BCSU
[LTG=<number>],[LTU=<number>],[EBT=<number>];
Beispiel
1.
Regenerieren aller Baugruppen in der Anlage.
Eingabe:
REG-BCSU:;
Ausgabe:
EINR-BCSU:PER,1,1,61,"Q2144-X ",0,0,,NEIN,300,700,300,A;
EINR-BCSU:PER,1,1,67,"Q2158-X ",1,0,,NEIN,300,700,300,A;
EINR-BCSU:PER,1,1,73,"Q2115-X ",0,0,,NEIN,,,,A;
EINR-BCSU:PER,1,1,79&&85,"Q2150-X ",0,0,,,,,,A;
EINR-BCSU:PER,1,1,91,"Q2141-X ",0,0,,,,,,A;
EINR-BCSU:PER,1,1,97,"Q2025-X300",0,0,,,,,,A;
EINR-BCSU:PER,1,1,103,"Q2121-X ",0,0,,,,,,A;
EINR-BCSU:PER,1,2,31,"Q2117-X ",0,0,,,,,,A;
EINR-BCSU:PER,1,2,55,"Q2214-X ",0,0,,,,,,A;
EINR-BCSU:PER,1,2,61,"Q2208-X100",0,0,,,,,,A;
EINR-BCSU:DIU,1,2,79,"Q2096-X200",0,,,,,0,,,,,A;
EINR-BCSU:DIU,1,2,85,"Q2096-X200",0,,,,,0,,,,,A;
EINR-BCSU:DIU,1,2,91,"Q2096-X200",0,,,,,0,,,,,A;
EINR-BCSU:DIU,1,2,97,"Q2096-X200",0,,,,,0,,,,,A;
EINR-BCSU:PER,1,2,103,"Q2235-X ",0,0,,,,,,A;
EINR-BCSU:PER,1,2,109,"Q2235-X100",0,0,,,,,,A;
EINR-BCSU:DIU,1,2,115,"Q2096-X200",0,,,,,0,,,,,A;
EINR-BCSU:PER,1,2,121,"Q2174-X ",0,0,,,,,,A;
OpenScape 4000 V11, Band 1: AMO Beschreibungen, Servicedokumentation, Ausgabe 2