175.4
Parameterbeschreibung
ACTION
Aktion der Sicherheitstechnik
Eingabeart
:
gekettete Einzelwerte;
erforderlich (EINRICHTEN, AENDERN)
wahlfrei (LOESCHEN)
Mögliche Werte
:
Die möglichen Einzelwerte sind aus den
DB_M_RS_ACTION_SET Werten abgeleitet.
ASSBLAM
= DB_RS_ASSOC_BLOCK_AM
ASSOCBLK
= DB_RS_ASSOC_BLOCK
CHANOOS
= DB_RS_SM_CHAN_OOS
BDOOS
= DB_RS_BOARD_OOS
HARDREST
= DB_RS_HARD_RESTART
HRCCZZA
= DB_RS_HR_CC_ZZ_ACTIVE
HRCCZZS
= DB_RS_HR_CC_ZZ_STANDBY
HREXSRRE
= DB_RS_HR_EXEC_SR_REFUSED
HRLTGZZA
= DB_RS_HR_LTG_ZZ_ACTIVE
HRLTGZZS
= DB_RS_HR_LTG_ZZ_STANDBY
INSERV
= DB_RS_IN_SERVICE
LBCOOS
= DB_RS_SM_LBC_OOS
LCXREST
= DB_RS_SM_LCX_RESTART
LOCKAM
= DB_RS_SPERREN_AM
NOACT
= DB_RS_NO_ACTION
NOACTAM
= DB_RS_NO_ACTION_AM
OOSAM
= DB_RS_OUT_OF_SERVICE_AM
OUTSERV
= DB_RS_OUT_OF_SERVICE
PARTBLK
= DB_RS_PART_BLOCK
PARBLAM
= DB_RS_PART_BLOCK_AM
RELOAD
= DB_RS_RELOAD
RELOCC
= DB_RS_RELOAD_CC
RELOLTG
= DB_RS_RELOAD_LTG
RESCSN
= DB_RS_RESET_CSN
RESET
= DB_RS_RESET
SOFTREST
= DB_RS_SOFT_RESTART
SPERRE
= DB_RS_SPERREN
SRCC
= DB_RS_SOFT_RESTART_CC
SRLTG
= DB_RS_SOFT_RESTART_LTG
STATIST
= DB_RS_FAULT_STATISTIC
SWITCCG
= DB_RS_SWITCH_CCG
SWITLTG
= DB_RS_SWITCH_LTG
SWITSWU
= DB_RS_SWITCH_SWU
ALTKZ
gibt altes Fehler-Schlüsselkennzeichen an
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
A
= Alarmmeldung
B
= Beginnmeldung
E
= Endemeldung
F
= Fehlermeldung
G
= Gutmeldung
H
= Hinweismeldung
U
= Undefiniertes Fehlerelement
ALTNR
gibt alte Fehlernummer an
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
Siehe SHB-Band ’Sicherheitstechnik’
A30950-S37-X110-*-20, Kapitel 6
ASD
aktuelle symbolische Ausgabegeräte, an die die Meldung geschickt wird.
Eingabeart
:
1 bis 8 gekettete Einzelwerte, wahlfrei
:
1 bis 9 gekettete Einzelwerte, wahlfrei
Mögliche Werte
:
DPT1, DPT2, DPT3, DPT4,
AC, AFR, MAP, SICO, bzw.
DPT1, DPT2, DPT3, DPT4,
AC, MAP, AFR1, AFR2, AFR3 und
ALL (nur Aktion LOESCHEN)
NDP4 (nur Aktion AENDERN/LOESCHEN TYP=MID)
AUSWA
Auswahl
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
J, N
CSD
konfigurierte symbolische Ausgabegeräte, an die die Meldung geschickt wird.
Eingabeart
:
1 bis 8 gekettete Einzelwerte, wahlfrei
:
1 bis 9 gekettete Einzelwerte, wahlfrei
Mögliche Werte
:
DPT1, DPT2, DPT3, DPT4,
AC, AFR, MAP, SICO, bzw.
DPT1, DPT2, DPT3, DPT4,
AC, MAP, AFR1, AFR2, AFR3 und
ALL (nur Aktion LOESCHEN)
NDP4 (nur Aktion AENDERN/LOESCHEN TYP=MID)
DEV
konfigurierte Ausgabegeräte der Schalterfunktion, an die die Meldung geschickt wird.
Eingabeart
:
1 bis 8 gekettete Einzelwerte, Angabe eines Geraetes erforderlich
Mögliche Werte
:
DPT1, DPT2, DPT3
AC, AFR1, AFR2, AFR3
EVENT
Meldungsklasse
Eingabeart
:
gekettete Einzelwerte oder ALL
(beim Einrichten nur ein Einzelwert),
erforderlich
Mögliche Werte
:
Die möglichen Einzelwerte sind aus den
DB_M_RS_EVT_SET Werten abgeleitet.
ACM
= DB_RS_E_ACM
ALARM
= DB_RS_E_ALARMWORT
ALUM
= DB_RS_E_ALUM
AM
= DB_RS_E_AM
AMO
= DB_RS_E_AMO
BOARD
= DB_RS_E_BOARD
CCH
= DB_RS_E_CCH
CG
= DB_RS_E_CG
CHACOM
= DB_RS_E_CHARGE_COM
CIR
= DB_RS_E_CIR
CMS
= DB_RS_E_CMS
CONF
= DB_RS_E_CONF
CP
= DB_RS_E_CP
CPMSG
= DB_RS_E_CP_MSG
DB
= DB_RS_E_DB
DBSYNC
= DB_RS_E_DBSYNC
DCL
= DB_RS_E_DCL
DEP
= DB_RS_E_DEP
DH
= DB_RS_E_DH
DMS
= DB_RS_E_DMS
DRIVE
= DB_RS_E_DRIVE
GOINS
= DB_RS_E_GO_IN_SERVICE
HRCCA
= DB_RS_E_HR_CC_Z_A
HRCCSB
= DB_RS_E_HR_CC_Z_SB
HWY
= DB_RS_E_HWY
IOCC
= DB_RS_E_IOCC
IOCG
= DB_RS_E_IOCG
IOPSDC
= DB_RS_E_IOPD_DC
DRIVE
= DB_RS_E_DRIVE
GOINS
= DB_RS_E_GO_IN_SERVICE
HRCCA
= DB_RS_E_HR_CC_Z_A
HRCCSB
= DB_RS_E_HR_CC_Z_SB
HWY
= DB_RS_E_HWY
IOCC
= DB_RS_E_IOCC
IOCG
= DB_RS_E_IOCG
IOPSDC
= DB_RS_E_IOPD_DC
LBCLB
= DB_RS_E_LBC_LB
LCX
= DB_RS_E_LCX
LCXCHAN
= DB_RS_E_LCX_CHAN
LTGSMOFF
= DB_RS_E_LTG_SM_OFF
LTGSMON
= DB_RS_E_LTG_SM_ON
LTUC
= DB_RS_E_LTUC
MAP
= DB_RS_E_SIG_MELD
MBU
= DB_RS_E_MBU
MODSTATE
= DB_RS_E_MOD_ZUST
MTS
= DB_RS_E_MTS
NC
= DB_RS_E_NC
NCCALARM
= DB_RS_E_NCC_DEP_ALARM
NCCSBR
= DB_RS_E_NCC_START_SBR
NCCSTART
= DB_RS_E_NCC_START
NCCTIMER
= DB_RS_E_NCC_DEP_TIMER
NCCUPDAT
= DB_RS_E_NCC_UPDATE
OS
= DB_RS_E_OS
PCG
= DB_RS_E_PCG
PM
= DB_RS_E_PM
PP
= DB_RS_E_PP
PPH
= DB_RS_E_PPH
PROCINT
= DB_RS_E_PROC_INTERR
PS
= DB_RS_E_PS
PWFAIL
= DB_RS_E_NETZ_AUSF
REC
= DB_RS_E_REC
RESTSM
= DB_RS_E_RESTART_SM
SIT
= DB_RS_E_FEH_INBETRN_BE_AN
SITEND
= DB_RS_E_FEH_INBETRN_BE_EN
SIU
= DB_RS_E_SIU
SM
= DB_RS_E_SM
SMAM
= DB_RS_E_SM_AM
SMAS
= DB_RS_E_SM_AS
SMCR
= DB_RS_E_SM_CR
SMDB
= DB_RS_E_SM_DB
SMDEP
= DB_RS_E_SM_DEP
SMDP
= DB_RS_E_SM_DP
SMINS
= DB_RS_E_SM_INS
SMIP
= DB_RS_E_SM_IP
SMMB
= DB_RS_E_SM_MB
SMMEM
= DB_RS_E_SM_MEM
SMNACK
= DB_RS_E_SM_NEGATIVE_ACK
SRCC
= DB_RS_E_SR_CC
STBY
= DB_RS_E_STBY
SWUDP
= DB_RS_E_SWU_DP
SWUINT
= DB_RS_E_SWU_INT
SWUIP
= DB_RS_E_SWU_IP
SWUMEM
= DB_RS_E_SWU_MEM
SYS
= DB_RS_E_SYS
SYSLEXC
= DB_RS_E_SYSL_EXCEPT
SYSLOS
= DB_RS_E_SYSL_OS_ERROR
SYSQUOFL
= DB_RS_E_SYSDEP_QUEUE_OFLOW
TERM
= DB_RS_E_TERM
TIMEDATE
= DB_RS_E_TIME_DATE
VECO
= DB_RS_E_VECO
XENIX
= DB_RS_E_XENIX
ALL (nur Aktionen LOESCHEN, SETZEN und ABFRAGEN)
FORMAT
Ausgabeformat im Zweig EVT
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
STA (Ausgabe Status)
SEV (Ausgabe Daten der FET-Einträge)
IDX
Index der Meldung in der FET
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
0000 - 9999
KZ
Meldung-Schlüsselkennzeichen
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
A
= Alarmmeldung
B
= Beginnmeldung
E
= Endemeldung
F
= Fehlermeldung
G
= Gutmeldung
H
= Hinweismeldung
U
= Undefiniertes Fehlerelement
NEUKZ
gibt neues Fehler-Schlüsselkennzeichen an
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
A
= Alarmmeldung
B
= Beginnmeldung
E
= Endemeldung
F
= Fehlermeldung
G
= Gutmeldung
H
= Hinweismeldung
U
= Undefiniertes Fehlerelement
NEUNR
gibt neue Fehlernummer an
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
siehe Band Sicherheitstechnik
A30950-S37-X110-*-20, Kapitel 6
NR
Meldungsidentifikationsnummer
Eingabeart
:
gekettete Einzelwerte, Bereiche,
erforderlich
wahlfrei (ABFRAGEN vom Typ FST)
Mögliche Werte
:
siehe Band Sicherheitstechnik
A30950-S37-X110-*-20, Kapitel 6
OUTPUT
Ausgabeerlaubnis für Signalisierungsmeldung
Eingabeart
:
Einzelwert, wahlfrei
Mögliche Werte
:
FREE, LOCK
PRIO
Priorität der Signalisierungsmeldung
Eingabeart
:
Einzelwert, wahlfrei
erforderlich (EINRICHTEN, AENDERN vom Typ FST)
Mögliche Werte
:
E1 bis E9
M1 bis M9
SCHALTER
Verzweigungsparameter
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
IMPTMSG
= zwangsweise important message
FILTER
= nur restart und special messages
ALLMSG
= alle Meldungen
SHORTFM
= Meldungen in Kurzform
STATE
Status der Meldungsklasse
Eingabeart
:
Einzelwert, wahlfrei
Mögliche Werte
:
UNDEF, LOCK, FREE, OOS
TEXT
Indiviueller Text
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
Textstring, max. 74 Zeichen, in " eingeschlossen
TYP
Verzweigungsparameter
Eingabeart
:
Einzelwert, erforderlich
Mögliche Werte
:
ALL
= Namen und Werte aller Meldungsklassen
ALM
= Alarmspeicher
EVT
= EVENT
FST
= Fehlerelement-Sondertabelle
MID
= Message Identification
NID
= New Message Identification
SIF
= SIT-interne Fehlerstatistiktabelle
SCHALTER
= Schalterfunktion der SWITCH_TAB
STATUS
= Abfragen STATUS
SYSTEM
= Abfragen SYSTEM STATUS HICOM 300 E
Parametergruppen
In folgenden Aktionen wurden Parametergruppen definiert:
•
Aktion AENDERN (TYP=EVT): Parameter STATE, ASD und CSD;
•
Aktion AENDERN (TYP=MID): Parameter OUTPUT, PRIO, ASD und CSD;
•
Aktion LOESCHEN (TYP=EVT, MID): Parameter ASD und CSD;
•
Aktion EINSCHALTEN: Parameter DEV
•
Aktion AUSSCHALTEN: Parameter DEV
Es ist jeweils mindestens ein Parameter anzugeben.
OpenScape 4000 V11, Band 1: AMO Beschreibungen, Servicedokumentation, Ausgabe 2
, ID:
P31003H31B0S107027620
©
11/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.