7.3
Parameter Descriptions
ACTYPE
AC-Type
Type of Input
:
Single value, optional
Possible Values
AC4
ac connect to slmo or slmq.
ACWMQ
ACWIN with multiple queue mode
ACWMQIP
ACWINIP with multiple queue mode
ACW2Q
ACWIN with double queue mode.
ACW2QIP
ACWINIP with double queue mode.
Default Value
:
AC4
AMOALTRT
amo alternate routing
Type of Input
:
Single value
ADD, CHANGE:
1 single value,optional
Possible Values
:
YES,NO
Default Value
:
NO
ATNDNO
Attendant calling number
Type of Input
:
Single value, mandatory
ADD:
1 single value, mandatory
DELETE, CHANGE:
1 to 2 values, mandatory,
concatenated with & or &&
DISPLAY, REGENERATE:
1 to 2 values, optional,
concatenated with & or &&
Possible Values
:
0 - 9, up to 12 characters, ATNDNO must exist in numbering plan
CLASSMRK
DNIL classmarks
Type of Input
:
0 to 4 single values, concatenated with &, optional
Possible Values
EC
Echo Cancellation
G711
Voice compression via G711
G729
Voice compression (mandatory) according to G.729A
G729OPT
Voice compression (optional) according to G.729A
INIT
Echo Cancellation, G711, G729OPT
NONE
no ip classmarks activated
VAD
Voice activity detection
HG3530
bandwidth control for IP phone subscriber
HG3550
bandwidth control for IP trunk
Default Value
:
INIT
Action ADD
CLUSTID
Cluster ID
Type of Input
:
Single value
optional (ADD)
optional (CHANGE)
Possible Values
:
0 - 512
should be 0 for all TDM Phones
should be greater than 0 for all HFA Phones
Default Value
:
0
Action ADD
COS
Class of service of this ATND
Type of Input
:
Single value
mandatory (ADD)
optional (CHANGE)
Possible Values
:
1 - 1000
The ATND COS for incoming calls must at least include unrestricted long distance service and unrestricted tie-line access. It is not necessary to verify an ATND’s COS for outgoing calls.
DELOPT
Deletion option
Type of Input
:
Single value, mandatory
Possible Values
ALL
delete attendant
PUBNUM
public telephone number
SPDC
speed calling central
STNOOOS
alternate routing number for OOS
STNOAPE
alternate routing number for AP emergency
DPLN
Feature access group, dial plan
Type of Input
:
Single value,
mandatory (ADD)
optional (CHANGE)
Possible Values
:
0 - 15
EOVR
Emergency override/forced hold
Type of Input
:
Single value, optional
Possible Values
:
Y
[yes]
N
[no]
Default Value
:
N
LANG
Language parameter for ATND
Type of Input
:
Single value, optional
Possible Values
:
BRA
= brazilian
CAT
= catalan
CFR
= canadian french
CROAT
= croatian
CZ
= czech
DAN
= danish
DUT
= dutch
ENG
= english
FIN
= finnish
FRE
= french
GER
= german
GRE
= greek
HU
= hungarian
ITA
= italian
NOR
= norwegian
PO
= polish
POR
= portuguese
RUS
= russian
SLOVAK
= slovakian
SLOVEN
= slovene
SPA
= spanish
SWE
= swedish
TUR
= turkish
Default Value
:
GER
LCOSV
LCR class of service for voice-services of this attendant
Type of Input
:
Single value,
optional (ADD, CHANGE)
Possible Values
:
1 - 1000 (ADD, CHANGE)
Default Value
:
1
The AC is to be assigned a class of service which contains all LCR authorizations if possible.
LCOSV = 1 is reserved for this purpose.
NEWNO
New station number for the ATND
Type of Input
:
Single value
optional
Possible Values
:
0 - 9, up to 6 characters, NEWNO must exist in the numbering plan
NNO
virtual node identification: level2-level1-level0
Type of Input
:
1 to 3 single values, concatenated with -, optional
Levels have to be filled from low to high (e.g. not allowed: 1-0-12)
Possible Values
:
0 - 999
level0
0 - 253
level1
0 - 29
level2
NPI
Numbering plan identification
Type of Input
:
Single value, optional
Possible Values
:
ISDN
ISDN (E.164)
PNP
private numbering plan
UNKNOWN
unknown
Default Value
:
UNKNOWN
PEN
Port equipment number of the ATND: LTG-LTU-SLOT-CCT
Type of Input
:
4 single values, concatenated with -, mandatory
Possible Values
:
<gg-uu-sss-cc>
numeric, 0-254
gg
LTG 1
uu
LTU 1 - 99 (dependent on the system)
sss
SLOT 1 - 121
cc
CCT
PUBNUM
Public telephone number
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, up to 15 characters
PUBNAME
Public name
Type of input
Single value, optional
Possible Values
Text, max 22 characters
SATNDNO
Secret attendant calling number
Type of Input
:
Single value, optional
Possible Values
:
NO
= the ATND number does appear on the internal or external station’s display
YES
= the ATND number does not appear on the internal or external station’s display
ONLYEXT
= the ATND number does not appear on the external station’s display. A default number will be displayed; assigned by the AMO-
KNMAT
.
Default Value
:
NO
SCRGRP
Source group index
Type of Input
:
single value, optional
Possible Values
:
0 - 255
Default Value
:
0
SPDC1
Central speed dialer 1
Type of Input
:
Single value, optional
Possible Values
:
0 - 15
Default Value
:
0
SPDC2
Central speed dialer 2
Type of Input
:
Single value, optional
Possible Values
:
0 - 15
Default Value
:
0
STNOOOS
subscriber individual alternate routing no for OOS
Type of Input
:
Single value, optional
Possible Values
:
keyed numeral,up to 22 characters
Default Value
:
STNOAPE
subscriber individual alternate routing no for AP emergency 2
Type of Input
:
Single value, optional
Possible Values
:
keyed numeral,up to 22 characters
Default Value
:
TON
Type of number
Type of Input
:
Single value, optional
Possible Values
:
ABBR
abbreviated number
INTERNAT
international number
L1REGIO
level 1 regional number
L2REGIO
level 2 regional number
LOCAL
local number
NATIONAL
national number
SUBSCR
subscriber number
UNKNOWN
unknown
Default Value
:
UNKNOWN
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.