8.4
Parameter Description
ACT
Activation parameter for night option
Type of Input
:
single value, optional
Possible Values
:
ACT
activate night option
ACTION
mobile HFA logging action, branching parameter
Type of Input
:
single value, mandatory
Possible Values
:
MLOGON
LOGON of the mobile HFA visitor
MLOGOFF
LOGOFF of the mobile HFA visitor
ALERTVOL
Optiset / Optipoint 500 alert tone volume
Type of Input
:
single value, 3. parameter of a min-1-group
Possible Values
:
numeric, 0 to 7
ATNDGR
Attendant group number
Type of Input
:
1 to 16 single values, concatenated with & or &&,
mandatory
(ADD,TYPE=ATNDGR)
single value, optional
Possible Values
:
numeric, 0 to 15
CALLVOL
Optiset handset volume
Type of Input
:
single value, 4. parameter of a min-1-group
Possible Values
:
numeric, 0 to 7
CFVAR
call forwarding variant
Type of Input
:
single value, mandatory
(ADD,TYPE=STN,FEATCD=FWD)
single value, optional
(DELETE,FEATCD=FWD)
Possible Values
:
STATIONF
station call forwarding fix
STATIONV
station call forwarding variable
SYSTEM
system call forwarding
CLIENT
Circuit client data
COND
Condition for LOGOFF
Type of Input
:
single value, optional
Possible Values
:
IDLESTN
LOGOFF only, when station is idle
UNCOND
unconditional LOGOFF
DESTNO
forwarding destination number
Type of Input
:
single value, optional
Possible Values
:
0-9,*,#,A-D,up to 22 characters
DISPCONT
optipoint display contrast
Type of Input
:
single value, 7.parameter of a min-1-group
Possible Values
:
numeric, 0-7
DTYPE
diversion type
Type of Input
:
1 to 5 single values, concatenated with &, optional
(DELETE,FEATCD=FWD)
single value, optional
(ADD,TYPE=STN,FEATCD=FWD)
Possible Values
:
CFB
call forwarding busy
CFBNR
call forwarding busy/no reply
CFDEV
call forwarding device
CFDND
call forwarding do not disturb
CFNR
call forwarding no reply
CFU
call forwarding unconditional
FEATCD
User feature code; specifies features with user data to be saved
Type of Input
:
1 to 2 single values, concatenated with &, mandatory
(ADD,TYPE=ITR)
single value, mandatory
(ADD,TYPE=STN,DELETE)
Possible Values
:
DND
act./deact. ft. do not disturb
(ADD,TYPE=STN,DELETE)
CWT
ACTIVATE/DEACTIVATE FT. CALL WAITING/SECOND CALL
DNDGR
act. ft. do not disturb - group
(ADD,TYPE=ITR)
FWD
act./deact. ft. call forwarding
(ADD,TYPE=STN,DELETE)
ISTR
act. ft. int.self-dial traffic restr.
(ADD,TYPE=ITR)
OPTISET
indiv. settings for optiset and optipoint 500
(ADD,TYPE=STN)
OUTHUNT
switch out of hunt group
(ADD,TYPE=STN)
RCUTOFF
ringer cutoff
(ADD,TYPE=STN)
REMIND
activate ft. reminder
(ADD,TYPE=STN)
REPSECR
activate ft. representative for secretary
(ADD,TYPE=STN)
RNGXFER
activate ft. ring transfer executive/secretary
(ADD,TYPE=STN)
VARRING
Variable Ring Time
(ADD,TYPE=STN)
VCR
activate ft. voice call reject
(ADD,TYPE=STN)
FWDDESK
NO ANSWER ADVANCE TIMER FROM CLIENT TO DESK FOR OSMO&CIRCUIT
The first Routing step is the OSMO/Circuit Client. The Client rings until the FWDDESK _forward to desk timer expires.
Type of Input
single value, optional
Possible Values
numeric, 0-30
FWDCELL
NO ANSWER ADVANCE TIMER FROM DESK TO MOBILE FOR OSMO&CIRCUIT
Upon FWDDESK timer expiry the call is forwarded to the deskphone and FWDCELL timer is started if mobile number/alternative number is available otherwise FWDVM is started. The incoming call is still signaled at the Client.
Type of Input
single value, optional
Possible Values
numeric, 0-30
FWDVM
NO ANS ADV TIMER TO VM FOR OSMO & TO CFNR DEST FOR CIRCUIT
Upon expiry of FWDCELL forward to mobile the call is forwarded to the mobile number/alternative device and FWDVM is started.
Upon expiry of FWDVM forward to Voice Mail the call is forwarded to the deskphones No Answer Destination (Voicemail for many users)
Type of Input
single value, optional
Possible Values
numeric, 0-30
FWDCFNR
NO ANSWER ADVANCE TIMER FOR OSMO ONLY
Type of Input
single value, optional
Possible Values
numeric, 0-30
HOMEPIN
PIN of the visitor
Type of Input
:
single value, mandatory
Possible Values
:
alphanumeric except #,
max. 12 digits
HOMESTNO
home station number of the visitor
Type of Input
:
single value, mandatory
Possible Values
:
0...9,*,#,A...D
max. 22 digit
INSECLNK
controls the logon in case of security ON/OFF
Type of Input
single value, optional
Possible Values
Y
YES
YES
YES
N
NO
NO
NO
ITR
Internal restriction group / closed user group
Type of Input
:
0 to 16 single values, concatenated with & or &&, optional
(ADD,TYPE=ITR)
single value, optional
(DISPLAY,TYPE=ITR/REGENERATE,TYPE=ITR)
Possible Values
:
numeric, 0 to 15
Note
:
If parameter ITR is not specified, the function GRP_DND_ALL or ITR_ALL is carried out
ITYPE
incoming seizure
Type of Input
single value, optional
Possible Values
INT
internal calls
EXT
external calls
GEN
all calls
NOPT
Night options for attendant
Type of Input
:
single value, mandatory
Possible Values
:
numeric, 1 to 8
REMIND
Time for reminder, with format DHHMM (within 24 hours)
Type of Input
0 to 12 single values, concatenated with &, mandatory
Possible Values
numeric, 00000-02359, 10000-12359, 20000-22359,
30000-32359, 40000-42359, 50000-52359,
60000-62359
Note
:
The time entry contains the weekday and time, whereby
0 = Sunday, 1 = Monday, 2 = Tuesday, 3 = Wednesday,
4 = Thursday, 5 = Friday, 6 = Saturday .
RINGSOUN
Optiset / Optipoint 500 ringer sound
Type of Input
:
single value, 2. parameter of a min-1-group
Possible Values
:
numeric, 0 - 15
0 -15
Optipoint 500
0 - 7
Optiset E
Note
:
The values 1 -16 will be displayed on the Optipoint 500 device
RINGVOL
Optiset / Optipoint 500 ringer volume
Type of Input
:
single value, 1. parameter of a min-1-group
Possible Values
:
numeric, 0 - 7
RNGTIME
Ring Time
Type of Input
:
single value, optional
Possible Values
:
numeric, 0 - 60
ROLLVOL
Rollover volume
Type of Input
:
single value, 8. parameter of a min-1-group
Possible Values
:
numeric, 0 - 7
ROOMCHAR
room characteristic for hands-free talking
Type of Input
:
single value, 6. parameter of a min-1-group
Possible Values
:
ECHO
echoing room
NORMAL
normal room
QUIET
quiet room
SI
Service indicator
Type of Input
:
1 to 8 single values, concatenated with &, mandatory
(ADD,TYPE=STN,FEATCD=FWD)
single value, optional
(DELETE,FEATCD=FWD)
Possible Values
:
AUDIO3K1
digital audio device 3,1 khz
DTE
service data terminal equipment for system devices
FAX
service facsimile for system devices
FAXG23
facsimile group 2&3
FAXG4
facsimile group 4
GENSRVC
general service
SPCH
speech
TEL3K1
telephony (3,1 khz, anate)
TEL7K
telephony 7khz
TONES
unrestricted digital information with tones
UDI
unrestricted digital information
VCE
service indicator for system devices
VIDEOTEL
videotelephony
SIINHT
Service indicator for switch on of hunt group
Type of Input
1 to single values, concatenated with &, mandatory
Possible Values
DTE
service data terminal equipment for system devices
FAX
service facsimile for system devices
VCE
service voice for system devices
SIOUTHT
Service indicator for switch out of hunt group
Type of Input
:
1 to single values, concatenated with &, mandatory
Possible Values
:
DTE
service data terminal equipment for system devices
FAX
service facsimile for system devices
VCE
service voice for system devices
SLKCONT
Display contrast for self labeling keys
Type of Input
:
single value, 9.parameter of a min-1-group
Possible Values
:
numeric, 0-7
SPKRVOL
Optiset loudspeaker volume
Type of Input
:
single value, 5. parameter of a min-1-group
Possible Values
:
numeric, 0 - 7
STNO
station number
Type of Input
:
0 to 30 single values, concatenated with & or &&, optional
(DISPLAY/REGENERATE,TYPE=STN)
single value, mandatory
(ADD,TYPE=STN/ DELETE)
Possible Values
:
numeric, up to 12 characters
TYPE
Branch parameter, desired subscriber feature option
Type of Input
:
single value, mandatory
(ADD/DELETE)
single value, optional
(DISPLAY/REGENERATE)
Possible Values
:
ATNDGR
attendant group number
(ADD/DISPLAY/REGENERATE)
ITR
internal traffic restriction
(ADD/DISPLAY/REGENERATE)
MOBHFA
LOGON/LOGOFF of mobile HFA user (ADD)
STN
station
(ADD/DISPLAY/REGENERATE)
VISSTNO
station number of the visited station
Type of Input
:
single value, mandatory
Possible Values
:
numeric,
max. 12 digits
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.