9.2.4
CHANGE-AFR
Changing the parameter list of an LDU FAMAFR. At least one of the parameters of the list must be specified.
Procedure Overview
Command Code
Parameter
CHANGE-AFR
LDU=<param>,{PRI=<number>,MAXF=<number>
,MAXFL=<number>,FSUPV=<number>
,SETUPLT=<number>,TRSTART=<number>
,PERIOD=<number>,RETRLT=<number>};
[,ACTTIME=<number>,MNEGCALL=<number>];
Example
In the FAMAFR2, change the priority of faults that are to be transmitted instantly, to 6, and set the maximum number of high-priority faults that are to be accepted within the time specified in parameter FSUPV to 10.
Input:
CHANGE-AFR:LDU=AFR2,PRI=6,MAXF=10;