9.3
Parameter Description
ACTTIME
ACTIVATIONTIME AFTER SWITCH OFF THROUGH AVALANCHE
Type of Input
:
Single value, optional (ADD)
(CHANGE)
Possible Values
:
0 - 60 (minutes)
COMP
Number of following lines to be compared
Type of Input
:
Single value
mandatory
(ADD)
Possible Values
:
0 to 5 (lines)
DEL
Selection parameter for delete
Type of Input
:
Single value
mandatory
(DELETE)
Possible Values
:
ALL, LINE
EACTION
End of fault action
UNDEF means no analysis of fault action
Type of Input
:
Single value
mandatory
(ADD)
Possible Values
:
NOACT, ADVISORY, BDOOS, LBCOOS,
LCXREST, CHANOOS, OUTSERV, INSERV,
RESET, SCHASWU, SCHALTG, SOFTREST,
ACTION04, HARDREST, RELOAD, UNDEF
ENUM
F-number of a fault action end
Type of Input
:
Single value
mandatory
(ADD)
Possible Values
:
Alphanumeric, 5 characters
FACTION
Start of fault action
UNDEF means no analysis of fault action
Type of Input
:
Single value
mandatory
(ADD)
Possible Values
:
NOACT, ADVISORY, BDOOS, LBCOOS,
LCXREST, CHANOOS, OUTSERV, INSERV,
RESET, SCHASWU, SCHALTG, SOFTREST,
ACTION04, HARDREST, RELOAD, UNDEF
FINO
Entry number index in fault pair list
Type of Input
:
Single value
mandatory
(DELETE)
Possible Values
:
1 to 99
FNUM
F-number of a fault action start
Type of Input
:
Single value
mandatory
(ADD)
Possible Values
:
Alphanumeric, 5 characters
FSUPV
Supervision time for fault pair alarm or maximum number of faults
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
0 to 99 (minutes)
LDU
Parameter for LDU FAMAFR addressed
Type of Input
:
Single value
mandatory
(ACTIVATE, DEACTIVATE,ADD, CHANGE,
DELETE, START)
optional
(DISPLAY, OUTPUT)
Possible Values
:
AFR1, AFR2, AFR3
MAXF
Maximum number of high-priority fault reports during FSUPV
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
1 to 999
MAXFL
Maximum number of low-priority fault reports during FSUPV
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
1 to 999
MNEGCALL
Maximum negative call setup
Type of Input
:
Single value, optional
optional
(ADD)
Group parameter
(CHANGE)
Possible Values
:
Numeric, 0-255
PAR
Selection parameter for LDU and fault pair table
Type of Input
:
Single value
mandatory
(ADD)
optional
(DISPLAY)
Possible Values
:
LDU, TAB
PERIOD
Number of days after which low-priority faults are transmitted
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
0 to 99 (days)
PRI
Priority setting (higher/equal=transmit, lower=store)
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
1 to 8
RETRLT
Maximum retransmission limit of a data block
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
0 to 9
SETUPLT
Fault memory occupancy level for transmission
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
1 to 90 (per cent)
TRSTART
Fixed time of day for transmission of low-priority fault reports
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
0 to 23 (hours)
0 to 59 (minutes)
TYPE
Selection parameter for activate/deactivate
Type of Input
:
Single value
, chained single values
mandatory
(ACTIVATE, DEACTIVATE)
Possible Values
:
LDU, PROT