11.3.1
ADD-ANSU
The system number is only entered in those database subsystems which can contain customer-specific data. Since the SWU database consists of several subsystems, the system number can also be selectively entered in certain DB subsystems only. Existing entries are overwritten. If individual values are entered for parameter SUSY, i.e. a system number is not to be entered in all DB subsystems, the system numbers of DB subsystems not to be processed are compared with the newly entered system number. If deviations are detected, Advisory H01 is output. An empty database is initialized with "EMPTY_DB_ZDBxxxxx". In addition, by entering parameter SP the system program number entered in the DIR file for the specified APS on the hard disk can be changed.
Note
The system program number in the APS (SP) is defined during SP production, and subsequent alteration (by means of ADD) is not permitted.
Procedure Overview
Command Code
Parameter
ADD-ANSU
TYPE=SYSNO,SYSNO=<string>,[SUSY=<string>];
|TYPE=SP,APS=<string>,SP=<string>;
Note
If the parameter SUSY is not specified, the system number is entered in all SWU subsystems.
Examples
The system number is entered in the SWU database subsystem DB_SUSY_ZDBCCDD1.
Input:
ADD-ANSU:SYSNO,"L31617S0001X ","ZDBCCDD1";
In APS S6-E50, the system program number is replaced by the number P30252X5521A10101.
Input:
ADD-ANSU:SP,"S6-E50SC","P30252X5521A10101";