21.5
Error Messages and Advisories
21.5.1
Error Messages
F01:
free
F02:
DEVICE <typeno> ALREADY ASSIGNED
F03:
IF TERMDESC = ACOL, THEN CNTRLNA MUST BE SPECIFIED TOO
F04:
IF TERMDESC = ARCVCO, THEN CNTRLNA MUST BE SPECIFIED TOO
F05:
IF TERMDESC = ARCVCO, THEN TIME MUST BE SPECIFIED TOO
F06:
IF TERMDESC = ARCVCO, THEN ANSLNT MUST BE SPECIFIED TOO
F07:
IF TERMDESC = ARCVCO, THEN ANSLN MUST BE SPECIFIED TOO
F08:
IF TERMDESC = DEACOL, THEN CNTRLND MUST BE SPECIFIED TOO
F09:
IF TERMDESC = PRTYPCO, THEN TFOUT MUST BE SPECIFIED TOO
F10:
IF TERMDESC = PRTYPCO, THEN TFIN MUST BE SPECIFIED TOO
F11:
LINE LENGTH GREATER THAN BUFFER LENGTH
F12:
LOGICAL DEVICE <ldevnam> ALREADY ASSIGNED
F13:
LINE <ln> ALREADY ASSIGNED
F14:
DEVICE <typeno> ALREADY ASSIGNED TO A LINE
F15:
free
F16:
DEVICE TYPE <devtype> IS NOT ASSIGNED
F17:
DEVICE <typeno> IS NOT ASSIGNED
F18:
LINE LENGTH OF DEVICE TYPE GREATER THAN LINE LENGTH OF DEVICE
F19:
INVALID VALUE
F20:
free
F21:
NO DEVICE TYPE ASSIGNED
F22:
DEVICE <typeno> IS NOT ASSIGNED TO ANY DEVICE TYPE
F23:
DEVICE TYPE <devtype> NOT ASSIGNED TO ANY TERMINAL OR
PRINTER WHICH CAN BE CHANGED BY ATCSM
F24:
free
F25:
free
F26:
TYPENO 7 CAN BE ASSIGNED ONLY TO DEVICE TYPE PT88
F27:
LINE COULD NOT BE DEACTIVATED
F28:
COMBINATION OF PARAMETER VALUES IN TERMDESC NOT VALID
F29:
LINE NOT ASSIGNED
F30:
DEVICE TYPE IS ASSIGNED TO DEVICE 1
The device type who is allocated to device 1 must not be changed or deleted.
F31:
DEVICE 1 NOT PROCESSED BY AMOS
F32:
FICTITIOUS DEVICE ASSIGNED
F33:
NO DEVICE TYPE ASSIGNED
F34:
A DEVICE TYPE ALREADY ASSIGNED TO DEVICE <typnu>
F35:
ASSIGNMENTS TO LINE 8 ARE NOT PROCESSED BY AMOS
F36:
LINE <ln> IS NOT ASSIGNED FOR AN ASYNCHRONOUS TERMINAL
F37:
DEVICE <typeno> IS ALREADY ASSIGNED TO DEVICE TYPE <devtype>
F38:
INVALID PASSWORD
F39:
NO FREE LIST AVAILABLE
F40:
NO INPUT AT PT88 POSSIBLE
F41:
DEVICE TYPE PT88 CAN ONLY BE ASSIGNED ONLY TO TYPENO 7
F42:
<ldevname> CAN NOT BE ASSIGNED TO A PT88
F43:
NO SUITABLE LOADWARE PRESENT
F44:
LOGICAL DEVICE <ldevname> IS ASSIGNED IN THE <tbl> TO SYMBOLIC
DEVICE <symdev>
F45:
DEVICE TYPE <devtype> HAS TO CONTAIN A VALID CONTROL CHARACTER
F46:
LINE NUMBER <ln> IS NOT VALID FOR TYPE <lntype>
lntype = "PSIO" or "TTYBSC"
F47:
IT IS NOT POSSIBLE TO DO MORE THAN 6 ALLOCATIONS FOR TYPE LINE
F48:
SWU NOT AVAILABLE
F49:
LINE <ln> IS NOT RESERVED FOR RMX
F50:
REMOVE AN EXISTING LINK BEFORE DOING THE CHANG
F51:
THERE DON'T EXIST ASNYCH OR V24 LINES IN A CPCI SHELF
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.