27.3
Parameter Description
ACTFC
Activate Flow Control
Type of Input
:
Single value, optional
Possible Values
:
YES
NO
Default Value
:
NO
ALARMNO
Alarm number
Type of Inut
:
Single value, optional
Possible Values
:
numeric, 0, 8-519
BCHL3530
Amount of b-channels for HG3530 function
Type of Inut
:
Single value, optional
Possible Values
:
numeric, 1-120
BCHL3550
Amount of b-channels for HG3550 function
Type of Inut
:
Single value, optional
Possible Values
:
numeric, 1-120
BCHL3570
Amount of b-channels for HG3570 function
Type of Inut
:
Single value, optional
Possible Values
:
numeric, 1-120
BCHLSIP
Amount of b-channels for SIP subscr. (HG3540) function
Type of Input
:
Single value, optional
Possible Values
:
numeric, 1-120
CCT
Circuit/trunk number
Type of Input
:
1 to 2 Single values or a value range (CHANGE)
Possible Values
:
0 to 254
Default Value
:
0 && max. range of specified board
CFIG
Specifies the configuration to be output
Either the reference or the actual configuration with thel peripheral modules can be output.
The "reference configuration" is the one entered in the database.
The "reference configuration" is modified by means of the functions "DELETE", "ADD", or "CHANGE" of this AMO.
"Actual configuration" refers to the actual configuration of the system. The actual configuration is modified by pulling or plugging modules.
Type of Input
:
single value, optional
Possible Values
CURR
actual configuration
:
EXP
reference configuration
Default Value
:
EXP
CHNGRSLN
Change prereserved HG3530, respectively HG3550 lines
Type of Inut
:
Single value, optional
Possible Values
:
numeric, 1-255
CIRCNT
Number of circuits to be configured for boards with changeable number of circuits
Type of Input
:
Single value, optional (ADD)
Possible Values
:
1 to 255
Default Value
:
value from UBGDAT
COFIDX
Index of cofi data file to be loaded
Type of Input
:
Single value, optional (CHANGE)
Possible Values
:
0 to 7
DEVTYPE
Device type
Type of Input
:
Single value, optional (CHANGE)
Possible Values
:
OPTISET
device OPTISET E
API
OPTISET with workstation protocol
FCTID
Function identification number for boards with more than one functions (e.g. SIUX, STMA, SLMO24)
Type of Input
:
Single value, optional (ADD, DELETE)
Possible Values
:
0 to 255
Valid at present:
2 for SIU type 2 (MFV)
3 for SIU type 3 (MFC)
4 for SIU - RDS functionality
5 for SIU - ANI signalling
6 for SIU - CIS multifrequency (MFS)
7 for SIU - Line Testing
peripheral boards see UBGDAT
Default Value
0
ADD-BCSU:DIU
0
ADD-BCSU:PER
0
ADD-BCSU:PERHW
0
ADD-BCSU:RG
0
ADD-BCSU:ACGEN
2
ADD-BCSU:SIUP
1
ADD-BCSU:TMD
1
ADD-BCSU:IPGW
0
DELETE-BCSU:PER
FCTID1
Function identification number for boards with more than one function
Type of Input
:
single value, optional (CHANGE)
possible Values
0 - 255
Valid at present:
see UBGDAT
Default Value
0
boards without function identification number
FCTID2
Function identification number for boards with more than one function
Type of Input
:
single value, optional (CHANGE)
possible Values
0 - 255
Valid at present:
see UBGDAT
Default Value
0
boards without function identification number
FIDX
File index of DEP LOCK TBL (1st PCM highway). This contains error code combinations for initiating soft locking/no action/special action treatment of errors on PCM highways of a TMD-BOS.
The error code combinations are defined with the ZAND AMO, parameter TYPE=DIUSL
Type of Input
:
Single value, optional
Possible Values
:
1 - 10
Default Value
:
1
FIDX1
File index of DEP LOCK TBL (1st PCM highway). This contains error code combinations for initiating soft locking/no action/special action treatment of errors on PCM highways of a DIUC or DIUC64.
The error code combinations are defined with the ZAND AMO, parameter TYPE=DIUSL
Type of Input
:
Single value, optional
Possible Values
:
1 - 10
Default Value
:
1
FIDX2
File index of DEP LOCK TBL (2nd PCM highway). This contains error code combinations for initiating soft locking/no action/special action treatment of errors on PCM highways of a DIUC64.
The error code combinations are defined with the ZAND AMO, parameter TYPE=DIUSL
Type of Input
:
Single value, optional
Possible Values
:
1 - 10
Default Value
:
1
HWYBDL
Highwaybundle
Type of Input
:
Single value, optional (ADD/CHANGE)
Possible Values
:
A
Highwaybundlel A
:
F
Highwaybundlel F: for overlayconfiguration
Default Value
:
A
IPADDR
IP gateway address (i.e 198.16.16.78) for payload connections from IP net to HHS
Type of Input
:
1 to 4 single values, concatenated with "."
:
mandatory (ADD)
:
mandatory ( CHANGE)
Possible Values
0 to 255
LTERM
Threshold value long
Type of Inpu
:
Single value, optional
Possible Values
:
100 to 5000
Default Value
:
see UBGDAT
LTG
Line trunk group specifications
Type of Input
:
Single value, mandatory (ADD, DELETE, CHANGE)
Single value, range, optional (DISPLAY, REGENERATE)
Type of Inpu
:
optional
(CHANGE)
TYPE=FLOWCTRL
:1 single value or 1 value range may be specified.
(DISPLAY)
TYPE=FLOWCTRL
:Up to 2 single values or 1 value range may be specified.
Possible Values
:
1 to 1
Default Value
:
1
LTU
Specification of the LTU of an LTG. The LTU shelves in the cabinet are consecutively numbered from top to bottom.
Type of Input
:
mandatory
1 single values or a range (TYPE=PER)
1 single values or a range,
optional (CHANGE)
Single value or a range, optional (DISPLAY, REGENERATE)
Type of Inpu
:
optional
(CHANGE)
TYPE=FLOWCTRL
:1 single value or 1 value range may be specified.
(DISPLAY)
TYPE=FLOWCTRL
:1 single values or 1 value range may be specified.
Possible Values
:
1 - 15 in HHS (Host Shelf)
16 not defined
17 - 99 in AP (Access Point Shelf)
Default Value
:
1 && max value of HW platform for shelves in HHS
:
17 to 99 for AP shelves (gap between LTU number max and 17 depends on the HW platform)
LWPAR
Index to LW parameter block for TMDN board
Type of Input
:
Single value, optional
Possible Values
:
1 - 200
Default Value
:
1
LWPAR1
Loadware parameterization of DIUC or DIUC64 (1st PCM highway)
This parameter assigns a specific parameter block defined by means of the LWPAR AMO, parameter TYPE=DIUC.
Type of Input
:
Single value, optional
Possible Values
:
1 - 6
Default Value
:
1
LWPAR2
Loadware parameterization of DIUC64 (2nd PCM highway)
This parameter assigns a specific parameter block defined by means of the LWPAR AMO, parameter TYPE=DIUC.
Type of Input
:
Single value, optional
Possible Values
:
1 - 6
Default Value
:
1
LWVAR
Loadware Variant
Type of Input
:
Single value, optional
Possible Values
:
0-9, A-Z
Default Value
:
0
Remark
:
The parameter LWVAR can only be declared in the initial configuration command for a board type (e.g. SLMA1), if the LWVAR is known to be greater than 0. In subsequent configuration commands for boards of the same type the parameter LWVAR will be ignored. Later changes to the loadware variant must be carried out with the ZAND AMO, TYPE=LOADWARE
MACADDR
MAC address of board
Type of Input
:
6 single values,concatenated with -, optional
Possible Values
:
hexadecimal, 0-FF
Remark
:
The parameter LWVAR can only be declared in the initial configuration command for a board type (e.g. SLMA1), if the LWVAR is known to be greater than 0. In subsequent configuration commands for boards of the same type the parameter LWVAR will be ignored. Later changes to the loadware variant must be carried out with the ZAND AMO, TYPE=LOADWARE
MFCTYPE
Specification of the working mode for SIU type 3, type 5, type 6
Type of Input
:
mandatory for SIU type 3, type 5, type 6
8 single values
If fewer values are entered, the last entered value is used to complete the set. If SIU is not type 3, type 5 or type 6 the parameter is not permitted
Possible Values
:
R2F
CCITT R2 forward
R2B
CCITT R2 backward
R1
CCITT R1
SOCFF
MFCSOCOTEL France forward
SOCEF
MFCSOCOTEL Spain forward (register signaling 2 out of 5 frequencies)
SOCE6F
MFCSOCOTEL Spain forward (register signaling 2 out of 6 frequencies)
SOCFB
MFCSOCOTEL France backward
SOCEB
MFCSOCOTEL Spain backward (register signaling 2 out of 5 frequencies)
SOCE6B
MFCSOCOTEL Spain backward (register signaling 2 out of 6 frequencies)
MFPB
MFP signalling backward
MFPF
MFP signalling forward
ANIB
ANI signalling backward
ANIF
ANI signalling forward
MFRSB
MFR signalling shuttle backward
MFRSF
MFR signalling shuttle forward
MFRPB
MFR signalling packed backward
MFRPF
MFR signalling packed forward
MTYPE
Type of module to be assigned
Type of Input
:
Single value, mandatory
Possible Values
:
PER
Periphery module
SIUP
Receiver (additional) SIU
RG
Ringing current generator module
ACGEN
Dialing ac generator module
DIU
Digital interface unit
PERHW
Base stations (perpheral HW)
TMD
TMD board
IPGW
IP gateway (STMI board)
Default Value
:
PER
OPMODE
Mode of operation of the ringing current or dialing ac generator
Type of Input
:
single value, required
Possible Values
:
for the ringing current generator
UN20H85V: ring current:unsymmetric 20 HZ 85 V (message waiting Thailand)
UN25H65V: ring current:unsymmetric 25 HZ 65 V
UN25H85V: ring current:unsymmetric 25 HZ 85 V
UN50H65V: ring current:unsymmetric 50 HZ 65 V
UN50H85V: ring current:unsymmetric 50 HZ 85 V
for the dialing AC generator
SY25H85V: ring current:symmetric 25 HZ 85 V
SY50H65V: ring current:symmetric 50 HZ 65 V
SY50H85V: ring current:symmetric 50 HZ 85 V
OPS
Mark stations on SLMA boards for off premises usage
Type of Input
:
Single value, optional
Possible Values
:
YES
NO
Default Value
:
NO
PARTNO
Specification of the module to be entered
(2nd and 3rd block of the code number)
Type of Input
:
single value
optional (DISPLAY)
required (ADD,DELETE)
Possible Values
:
code number in accordance with the table of permissible module types, e.g., "Q2057-X"
PARTNO1
Specification of the module to be changed
(2nd and 3rd block of the code number)
Type of Input
:
Single value
optional if SLOT is single value
mandatory if SLOT is range
Possible Values
:
Code number in accordance with the table of permissible module types, e.g. "Q2057-X"
PARTNO2
Specification of the new module
(2nd and 3rd block of the code number)
Type of Input
:
Single value, mandatory
Possible Values
:
Code number in accordance with the table of permissible module types, e.g. "Q2057-X"
PTERM
Threshold value permanent
Type of Inpu
:
Single value, optional
Possible Values
:
100 to 5000
Default Value
:
see UBGDAT
SLOT
Specification of the slot in the LTU. The slots are consecutively numbered corresponding to the labels on the module frame.
Type of Input
:
mandatory, for
(ADD)
TYPE=PER
Up to 4 single values and/or 1 or 2 value ranges can be entered
TYPE=SIUP, RG, ACGEN : single value
Type of Input
:
mandatory, for
(DELETE)
TYPE=PER
TYPE=PER: Up to 4 single values and/or 1 or 2 value ranges can be entered
TYPE=SIUP RG, ACGEN : single value
Type of Input
:
optional, for
(CHANGE)
TYPE=PARTNO
:Up to 2 single values or 1 value range may be specified.
TYPE=SIUP, RG, ACGEN : single value
If PARTNO01 (old code number) is not specified, the parameter SLOT must be entered as a single value.
Type of Input
:
optional
(CHANGE)
TYPE=FLOWCTRL
:1 single value or 1 value range may be specified.
(DISPLAY)
TYPE=FLOWCTRL
:Up to 2 single values or 1 value range may be specified.
Type of Input
:
optional,
(DISPLAY, REGENERATE)
a single value or a value range can be entered
If an LTU or an LTG range was entered, only range 1 && 121 is permitted for SLOT.
Possible Values
:
1, 7, 13, 19, 25, 31, 37, 43,49, 55,67, 73, 79, 85,91, 97, 103,
Non compact
109, 115, 121
25, 31, 37, 43,49, 55,61,67, 79, 85,91, 97, 103, 109, 115, 121
C, EC, ECX
60,72,78,84,90,96,102,108,114,120
CM80_BASE
61,73,79, 85,91, 97, 103, 109, 115, 121
CC80X
49,55,61,67,73,79,85,91,97,103
CC80F
1,2,3,5,6,7,8
INCH19
1,2,3,4,5,7,8,9,10
AP37009
1,2,3,4,5,6,8,9,10,11,12,13,14
AP370013
Default Value
:
whole range
SRCGRP
Source group index
Type of Input
:
1 to 2 single values, concatenated with "&"
optional
Possible Values
:
1 - 255
STERM
Threshold value short
Type of Inpu
:
Single value, optional
Possible Values
:
100 to 5000
Default Value
:
see UBGDAT
TDMLAW
TDMLAW value of trunking board
Type of Inpu
:
Single value, optional
Possible Values
:
numeric, 0-2
TSI
Terminal selection identifier
Type of Input
:
1 to 4 Single values or a value range (CHANGE)
Possible Values
:
1 to 8
Default Value
:
1
TYPE
Type of output
(CHANGE)
Type of Input
:
Single value, mandatory
Possible Values
:
PARTNO
Code number
DIU
DIU configuration
SIGNOFF
Set circuit or tsi to signed off (feat. "autoset relocate")
RELEASE
Set circuit or tsi from signed off to not connected (feat. "autoset relocate")
FLOWCTRL
Threshold values for flow control boards
HWYBDL
Highwaybundlel for overlayconfiguration.
TMD
TMDN board
IPGW
IP gateway
Type of Output
:
(DISPLAY)
Possible output types are:
Table Output
:
The reference and actual configurations with the peripheral modules are output in table format.
Statistics
:
For the reference or actual configuration of an LTG, the sum of the peripheral modules is output.
Mode
:
For modules with work modes (RG, WGEN, SIU type 3), the work modes are output.
Type of Input
:
single value, optional
TBL
table output
STAT
output of system statistics
MODE
output of work modes
PEN
port equipment number
PERHW
display base stations
FLOWCTRL
Threshold values for flow control boards
SRCGRP
Source group index
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5