30.3.1
ADD-BERUZ
Assign switchover times
The following is entered in the table:
•
Two time entries which determine the switchover time (COS1T, COS2T).
•
A pair of program switches (COS1, COS2).
•
One or more COS switchover groups and one or more days of the week.
Values already contained in the table are overwritten.
Procedure Overview
Command Code
Parameter
ADD-BERUZ
COSX=<number>,DAY=<number>,{COS1T=<hh-mm>
,COS1=<param>,COS2T=<hh-mm>,COS2=<param>};
Examples
1.
For COS switchover groups 0 to 2, entries are to be made for Monday to Friday and the times 6:55 each day for switchover to COS1 and 15:40 each day for switchover to COS2. The switchovers are to be carried out.
Input:
ADD-BERUZ:COSX=0&&2,DAY=1&&5,COS1T=06-55,COS1=ON,COS2T=15-40,COS2=ON;
2.
No switchover is to be made for groups 0 and 1 on the weekend, and the times 00.00 and 12.00 are to be entered for group 2, where switchover is to be carried initially only on Saturday.
a)
Input:
ADD-BERUZ:COSX=0&1,DAY=6&7,COS1=OFF,COS2=OFF;
b)
Input:
ADD-BERUZ:COSX=2,DAY=6&7,COS1T=00-00,COS1=ON,COS2T=12-00,COS2=ON;
c)
Input:
ADD-BERUZ:COSX=2,DAY=7,COS1=OFF,COS2=OFF;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5