35.4.1
Error Messages
F01:
LOADING OF MODULE DIRECTORY FILE (UBGDAT) IS NOT POSSIBLE
F02:
LTG NOT ASSIGNED
F03:
LTU NOT ASSIGNED
F04:
LTU NOT PRESENT
F05:
MODULE NOT ASSIGNED
F11:
MODULE <pen> NOT ACTIVATED (JOB ERROR)
(Activate not executed since an activate or deactivate job is currently being processed.)
F12:
MODULE <pen> NOT DEACTIVATED (NEQ)
(The module has not been deactivated since it is not assigned.)
F13:
MODULE <pen> NOT DEACTIVATED (WBT)
(The module has not been deactivated, since an incorrect module type is plugged.)
F14:
MODULE <pen> NOT DEACTIVATED (JOB ERROR)
(Deactivate not executed since an activate or deactivate job is currently being processed.)
F15:
MODULE <pen> IMPLAUSIBLE STATE
(GENNR,TRS,DEFIL AND/OR SIGNED_OFF)
(The module is in a state that cannot be evaluated.)
F16:
LTG NUMBER DOES NOT HAVE ADMISSIBLE VALUE
(The LTG with the specified LTG number does not exist.)
F17:
LTU NUMBER DOES NOT HAVE ADMISSIBLE VALUE
(The LG with the specified LTG number does not exist.)
F18:
INVALID SLOT NUMBER SPECIFIED FOR PARAMETER SLOT
(Invalid SLOT number specified. A mounting location is made up of six SLOTs; thus, valid SLOTs
are 1, 7, 13 etc. except SLOT 65. this SLOT contains the LTUC and is not switchable!)
F20:
LTG NOT PRESENT
F21:
MODULE <pen> NOT ACTIVATED - MODULE TYPE IS RG
THE MODULE CAN BE HANDLED WITH BCSU ONLY.
F22:
MODULE <pen> NOT ACTIVATED - MODULE TYPE IS ACGEN
THE MODULE CAN BE HANDLED WITH BCSU ONLY.
F23:
MODULE <pen> NOT DEACTIVATED - MODULE TYPE IS RG
THE MODULE CAN BE HANDLED WITH BCSU ONLY.
F24:
MODULE <pen> NOT DEACTIVATED - MODULE TYPE IS ACGEN
THE MODULE CAN BE HANDLED WITH BCSU ONLY.
F26:
MODULE <pen> IF LTC MODULE SWITCH ASSOCIATED MODULE
(The LTC module is switched along with the associated module.)
F27:
MODULE <pen> MODULE HAS NO STATISTICAL DATA
(Display not executed because this module has no statistic counter.)
F28:
MODULE <pen> DISPLAY OF STATISTICAL DATA CURRENTLY NOT POSSIBLE
(Display not executed since PP (pre-processing) is processing a different job at this time.)
F29:
MODULE <pen> TIME EXPIRED FOR DISPLAY OF STATISTICAL DATA
F33:
MODULE <pen> DISPLAY NOT POSSIBLE
(Display not executed since the module is in the state ’not present’ or ’not equipped’ or has an incorrect module type.
F34:
MODULE <lage> NOT SWITCHED - MODULE TYPE IS PSIO
BOARD CAN BE SWITCHED ONLY BY MEANS OF AMO
BSSM
. CHECK LCXNO:
DISP-
BCSM
:A1,SW; THEN SWITCH: ACT/DEACT-
BSSM
:UNIT=A1,TYPE=SWU,LCXNO=<?>;
F35:
OFFTYPE=DC NOT POSSIBLE FOR MODULE SLC16.
SWITCH OFF BY MEANS OF:
DEACT-BSSU:DI,^ltg^,^ltu^,^ebt^;
F36:
MODULE PART NUMBER OR FUNCTION IDENTIFICATION IS INVALID.
VALID VALUES CAN BE INVESTIGATED WITH THE DATA OF A CORRESPONDING BOARD BY USING AMO
BCSU
:
DISP-
BCSU
:TYPE=TBL,LTG=,LTU=,SLOT=;
F37:
MODULE ^ltg^,^ltu^,^ebt^ NOT ACTIVATED.
MODULE TYPE IS STMA2. THE MODULE CAN ONLY BE
ACTIVATED WITH ONTYPE BOARD BY AUL.
(UNCONDITIONAL LOADING)
F38:
BOARD @@.@@.@@@ TIMER EXPIRED FOR INTERROGATION OF STATISTICAL DATA.
F39
SPECIFIED BOARD IS NOT IN STANDBY DEFECT MODE.(STBYDEF, SEE DISPLAY-HFAB)
F40
SPECIFIED BOARD IS ALREADY ACTIVATED.SWITCHING BACK OF THE IP TERMINALS NOT POSSIBLE.
F41
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE BOARD TO WHICH THE IP TERMINALS HAVE BEEN SWITCHED (^ltg^.^ltu^.^ebt^) IS NOT IN NORMAL MODE.(SEE DISPLAY-HFAB).
F42
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE BOARD TO WHICH THE IP TERMINALS HAVE BEEN SWITCHED (^ltg^.^ltu^.^ebt^) IS LOCKED BY AMO.
F43
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE SPECIFIED BOARD IS NOT IN DC STATE DEFECTIVE OR NL.
F44
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE SPECIFIED BOARD IS NOT A MEMBER OF A RECONFIGURATION POOL.(SEE DISPLAY-
BPOOL
)
F45
SWITCHING BACK NOT POSSIBLE, SINCE THE RECONFIGURATION POOL ^poolno^ IS CONFIGURED WITH THE INVALID ATTRIBUTE HOPAUT=MULTI.(SEE DISPLAY-
BPOOL
).
F46
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE HISTORY INFO OF THE SPECIFIED BOARD DOES NOT CONTAIN THE LINK (SWITCHED AUTTO BRD: AND SWITCHED AUTFR BRD:) TO THE BOARD WHERE THE IP TERMINALS HAVE BEEN SWITCHED TO.(SEE AMO-
BPOOL
;)
F47
THE BOARD, FROM WHICH IP TERMINALS HAVE BEEN SWITCHED TO ^ltg^.^ltu^.^ebt^, IS NO LONGER MEMBER OF THE RECONFIGURATION POOL ^poolno^. (SEE AMO-
BPOOL
).
F48
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE ALLOWED AUTOMATICAL HOP COUNT ^hopcnt^ IS EXCEEDED. (SEE DISP-
BPOOL
)
F49
SWITCHING BACK OF IP TERMINALS IS NOT POSSIBLE, SINCE THE HISTORY INFO OF THE BOARD WHERE THE IP TERMINALS HAVE BEEN SWITCHED TO, IS INCONSISTENT.(SEE DISP-
BPOOL
)
F50
TIMER EXPIRED WHILE WAITING FOR THE ACKNOWLEDGEMENT MESSAGE FROM DC (^acktime^ sec).
F51
SWITCHING ^swtype^ OF IP TERMINALS IS NOT POSSIBLE, SINCE THE LINES FROM THE BOARD ^ltg^-^ltu^-^ebt^ COULD NOT BE RELOCATED. ORIGINAL CONFIGURATION AND STANDBY MODES ARE MAINTAINED.
F52
SWITCHOVER OF IP TERMINALS IS NOT POSSIBLE SINCE THE DESTINATION BOARD (OR LAN CONN.) ^ltg^-^ltu^-^ebt^ IS NOT IN READY STATE.
F53
SWITCHOVER OF IP TERMINALS IS NOT POSSIBLE SINCE THE DESTINATION BOARD ^ltg^-^ltu^-^ebt^ IS NOT A STMI2-HFA BOARD.
F54
SWITCHOVER OF IP TERMINALS IS NOT POSSIBLE SINCE THERE IS NO APPROPRIATE BOARD IN RECONFIGURATION POOL ^poolno^.
F55
SWITCHOVER OF IP TERMINALS IS NOT POSSIBLE SINCE THE BOARD ^ltg^-^ltu^-^ebt^ IS NOT MEMBER OF A RECONFIGURATION POOL(SEE DISPLAY-
BPOOL
).
F56
SWITCHOVER OF IP TERMINALS IS NOT POSSIBLE SINCE THE ^bdtype^ BOARD ^ltg^-^ltu^-^ebt^ IS NOT IN THE SMODE = ^stdmode^ (SEE DISPLAY-HFAB).
F57
SWITCHOVER OF IP TERMINALS IS NOT POSSIBLE SINCE THE <ziel> BOARD ^ltg^-^ltu^-^ebt^ IS NOT IN ^state^ STATE.
F58
BOARD DATA SEGMENT AND NON LW DATA READ/WRITE ERROR.
F59
THE BOARD ^ltg^-^ltu^-^ebt^ IS IN INVALID STANDBY MODE.(SEE DISPLAY-HFAB).
F60:
RES-BSSU:CGWSW=CGWSWBCK&STBYRDY&SWITCH; CAN NOT BE USED, IF THE BOARD IS CONFIGURED FOR SOFTGATE REDUNDANCY BY BPOOL.