39.3.2
CHANGE-CABA
Changes entries in the CABA table. At least the password and one other paramater must be given.
Procedure Overview
Command Code
Parameter
CHANGE-CABA
CABAPSW=<string>,{PROCID=<string>,CABA=<param>}
Examples
1.
Deactivate callback class of service for an entry in the CABA table with the password SZMCH.
Input:
CHANGE-CABA:SZMCH,,N;
Output:
CHANGE-CABA:SZMCH,,N;
H500: AMO CABA STARTED
AMO CABA -... CALL - BACK
CHANGE COMPLETED;
2.
Change the symbolic process name to DVAPROC2 for an entry in the CABA table with the password SZMCH.
Input:
CHANGE-CABA:SZMCH,DVAPROC2;
Output:
CHANGE-CABA:SZMCH,DVAPROC2;
H500: AMO CABA STARTED
AMO CABA -... CALL - BACK
CHANGE COMPLETED;