50.3
Parameter Description
GRNO
Number of the com group
Type of Input
:
Single value
:
optional (DELETE, ADD)
:
required ( DISPLAY, REGENERATE)
Possible Value
:
1-1024 (requested number of a group)
Default value
:
First available group number (ADD)
group number of which specified STNO is a member (DELETE).
MBNO
Member number of the station in the COM group
Used only in the ADD command
Type of Input
:
Single value, optional
:
chained single values, range(s), chained range(s)
Possible values
:
0 -99
Default value
:
--
SIZE
Size of the com Group
Used only in the ADD command
Type of Input
:
Single value, optional
Possible values
:
S small (0 - 9 members of a communication group)
L large (00 - 99 members of a communication group)
Default value
:
S small
INFO
Service informations, it is possible to assign a name to the COM group
Type of Input
:
Single value, optional
Possible values
:
SText, max. 20 digits
Default value
:
No entry
INFOPAT
Pattern for search of Service Information
Type of Input
:
Single value, optional
Possible values
:
SText, max. 20 digits
Default value
:
No entry
STNO
Station number
Type of Input
:
Single value,&, &&, max. 50 singel value
Possible values
:
1 - 6 digit
Default value
:
--
TYPE
Branch parameter for all COM groups, a specific COM group or a specific station
Type of Input
:
Single value,required
Possible values
:
ALL (All COM groups on a system)
:
GR (a specific COM group)
:
STN (a specific station)
Default value
:
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.