66.2.4
DISPLAY-DCIC / REGENERATE-DCIC
Using the function DISPLAY-DCIC, the parameters from one or more DCIs can be output. For this purpose, only the PEN need be specified. If a PEN range is specified, a search is made for assigned DCIs. If the PEN is not specified, the entire PEN range is searched.
The function REGENERATE can be used to output the parameters of one or more DCIs when they are interrogated, but in the form of position-oriented commands. The parameter INS is generated at this time in dependency on the current DC state of the DCI (if the DC state is = "NEQ", then INS = "N" , otherwise INS = "Y" ).
Procedure Overview
Command Code
Parameter
DISPLAY-DCIC
[PEN1=<gg-uu-sss-cc>],[PEN2=<gg-uu-sss-cc>];
REGENERATE-DCIC
[PEN1=<gg-uu-sss-cc>],[PEN2=<gg-uu-sss-cc>];
Examples
1.
Interrogate the parameters of the DCI at PEN 1-1-1-0.
Input:
DIS-DCIC:1-1-1-0;
Output in format 1:
DISPLAY-DCIC:1-1-1-0;
+-------------+--------+
| PEN | STNO |
+-------------+--------+
|01-01-001-00 | 2101 |
+-------------+--------+
Explanation:
PEN = Port equipment number of DCI
STNO = Station number of the associated telephone
Regenerate the DCIs in the range from 1-1-1-0 to 1-1-1-1.
Input:
REG-DCIC: 1-1-1-0,1-1-1-1;
Output in format 2:
ADD-DCIC:1- 1-1-0,2101,Y;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.