72.2.2
CHANGE DEFTM
When changing the measurement is started or stopped.
The following switches are used:
•
PMON:
Central switch for performance management (PM), needed to start/stop PM.
If this switch is off, all installed measurement objects of AMO-DEFTM have no effect.
The recording of measurement data begins only with the activating of this switch.
•
ALLON:
All objects, except processor load and the attendant console activity, are recorded by the measurement.
Is this switch set, all entries in the list of measurement objects have no effect.
Is this switch not set, then the measurement of measurement objects of the list of measurement objects takes place.
•
LOADON:
A special CDR record is generated every 10 seconds, containing processor load (SWU and ADP)
•
ACACTON:
Events of the attendant console (AC) will be monitored:
- AC activates/deactivates nightservice,
- AC pulls/reconnect the jack,
- AC is out of/in service.
Procedure Overview
Command Code
Parameter
CHANGE-DEFTM
{(min 1)PMON=<param>,ALLON=<param>,LOADON=<param>
,ACACTON=<param>};
Examples:
1.
Switch on the central switch for performance management (PM).
Input:
CHANGE-DEFTM:PMON=Y;
2.
Switch on all measurement objects.
Input:
CHANGE-DEFTM:ALLON=Y;
3.
Switch on of the measurement objects (from measurement object table).
Input:
CHANGE-DEFTM:ALLON=N;
4.
A special CDR record is generated every 10 seconds, containing processor load (SWU and ADP).
Input:
CHANGE-DEFTM:LOADON=Y;
5.
Activation/deactivation of nightservice at attendant console (AC).
Input:
CHANGE-DEFTM:ACACTON=Y;