77.5.1
EXEC-DISP
Procedure Overview
Command Code
Parameter
EXEC-DISPA
[PROCID=<param>];
Notes
a)
The AMO DISPA controls the Displayer installed in the processor specified. The AMO itself runs in the ADS.
b)
The AMO will remain in dialog mode for several minutes awaiting input. If no input is made, the AMO terminates automatically.
Example
Input:
EXEC-DISP:ALL;
Output:
H500: AMO DISPA STARTED
AMO DISPA VARIANT/VERSION F2/003 OF 1993-02-25
DISPLAYER VARIANT/VERSION G1/006 OF 1994-09-27
DISPLAYER-INPUT IN A1 PLEASE:
Input:
*END; * = Request for command input
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.