77.10
Parameter Description
ADR
Used in commands: DEF, DUMP, LST, PATCH, SET;
address (selector and offset) or required distance with regard to beginning of file
Type of Input
:
For DEF, LST, SET:
2 linked single values, mandatory
For DUMP, PATCH:
Single value, mandatory
Possible Values
:
For DEF, LST, SET:
Hexadecimals, 0000 - FFFF (e.g. 3BF0-387)
For DUMP, PATCH:
Hexadecimals 00000000 - FFFFFFFF
AREA
Used in commands: COPY, DEF, DEL, LST.
area for which the command is valid
Type of Input
:
For DEF, DEL, LST:
Single value, mandatory
For COPY:
2 linked single values, optional
(default value: RES-AMO)
Possible Values
:
ALL
AMO
HD
RES
all areas (DEL only)
AMO work area
hard disk save area
resident task area
CMD
Branch parameter,
defines the Displayer commands
Type of Input
:
Single value, mandatory
Possible Values
:
CHAR
COPY
DEF
DEL
DIST
DUMP
E
END
EV
FILE
LST
P
PATCH
SET
character output
copy
define
delete
distance between lines
dump file contents
file for editing
end
evaluate
file for saving definitions
list memory contents
processor
patch file contents
set memory contents
(See Functional Overview for explanation)
CONTINUE
Used in command: LST;
defines whether or not output is to be continued after 2000 byte
Type of Input
:
Single value, optional
Possible Values
:
Y
N
YES - Continue output
NO - Abort output
Default Value
:
Y
CTYPE
Used in commands: CHAR, COPY, DEF, DEL, DUMP, EV, LST, PATCH, SET;
defines the command interpretation more precisely
Type of Input
:
Single value, mandatory
Possible Values
:
For CHAR:
OFF
ON
ASCII characters off
ASCII characters on
For COPY:
DBL
DEF
Copy the database layout data
Not permitted for tracer in IS; input will be rejected and advisory H3 output
Copy the memory definitions from the storage location specified
For DEF:
ADR
The definition is executed with a symbolic address
LOGNAME
The definition is executed with a logical memory definition
For DEL:
DEF
Delete memory definitions in the storage location specified
For DUMP:
ADR
The dump is executed with a symbolic address
(combined selector and offset shows position with respect to beginning of file)
DA
The dump is executed with a direct address
(Position in file)
LOGNAME
The dump is executed with a logical memory definition
(combined selector and offset shows position in file)
For EV:
D
The decimals entered are converted to hexadecimals
H
The hexadecimals entered are converted to decimals
For LST:
ADR
Listing is executed with a symbolic address
DA
Listing is executed with a direct address
(combined selector and offset)
DEF
Listing of table structures of memory definitions
INT
High-level listing for integration
LOGNAME
Listing is executed with a logical memory definition
SW
High-level listing for switch processing
For PATCH:
ADR
Output is executed with a symbolic address
(combined selector and offset shows position with respect to beginning of file)
DA
Output is executed with a direct address (Position in file)
LOGNAME
Output is executed with a logical memory definition (combined selector and offset shows position in file)
For SET:
ADR
DA
LOGNAME
Output is executed with a symbolic address
Output is executed with a direct address
Change is executed with a logical memory definition
DISPLACE
Used in commands: DEF, PATCH, SET;
defines the position of the area in the array element which is to be changed or used as a relative address (=DISPLACEment)
Type of Input
:
Single value, mandatory
Possible Values
:
0 - 65535
FILE
Used in commands: E, FILE; file name of file to be edited or hard disk save area.
Type of Input
:
Single value, mandatory
Possible Values
:
valid filename
(z.B. ":PDS:TEST" oder ":DBD:TEST")
IDX
Used in commands: DEF, DUMP, LST, PATCH, SET;
defines either the index at which data is to be changed or output, or the index range of the specified array.
Type of Input
:
For DEF with CTYPE=ADR:
Single value, mandatory
For DEF with CTYPE=LOGNAME:
Range, mandatory
For DUMP, PATCH, SET:
Single value, linked single values and/or range(s), mandatory
For LST with CTYPE=LOGNAME:
Single value, linked single values and/or range(s), mandatory
Possible Values
:
0 - 65535 else
LEN
Used in commands: DEF, LST;
length of an array element in a logical memory definition
Type of Input
:
Single value, mandatory for DEF and
optional for LST
Possible Values
:
For DEF: 1 - 6000
For LST: 0 - 65535
NAME
Used in commands: COPY, DEF, DEL, DUMP, LST, PATCH, SET;
name of various elements used.
Type of Input
:
Single value, optional for COPY and LST,DEF
mandatory
Possible Values
:
text string
(e.g. "DASS_AM_STATIC_TASK_TBL")
NO
Used in commands: DIST, DUMP, EV, FILE, LST, PATCH, SET;
number of empty lines to be inserted in hexadecimal dump output, or number of decimal numbers to be converted to binary or hexadecimal for output, or number of memory definitions to be saved, or number of memory units to be changed or listed
Type of Input
:
Single value, optional for FILE; mandatory else
Possible Values
:
For DIST:
0 - 4
For EV:
0 - 2147483647
:
For FILE:
0 - 65535
For DUMP, LST:
1 - 1500
For PATCH, SET:
1 - 10
PROCID
Used in command P
Processor which contains the Displayer task to be accessed
Type of Input
:
Single value, optional
Possible Values
:
A1
Administration and Data Server
SEL
Used in command: LST;
selection criterion to be used (=SELection)
Type of Input
:
Single value, mandatory
Possible Values
:
HD
SCREEN
output as file to hard disk
output to screen
TBL
Used in command: DEF;
name of table which contains the address.
Type of Input
:
Single value, mandatory
Possible Values
:
text string
(e.g. "DASS_AM_STATIC_TASK_TBL")
TYPE
Used in commands: DEF, LST;
defines the type of address definition or the type of memory output.
Type of Input
:
Single value, mandatory
Possible Values
:
For DEF:
ADR
TBL
The address is to be held in the storage location specified
The address is to be held in the table specified at the location specified
For LST:
BCA
BCASA
BDI
CHDI
CHSI
DBDS
DCHS
DSB
FUPST
basic data of boot communication area
save area of BCA
DAAS_HW_BOARD_INF_TBL
DAAS_HW_CH_DEVICE_INF_TBL
DAAS_HW_CH_SERVICE_INF_TBL
DAAS_HW_BOARD_D_STATE_TBL
DASS_HW_CHAN_D_STATE_TBL
DAAS_DMS_SWITCH_BOARD
DASV_FBT_FAMUP_STATUS
RDV
SBDS
SCHS
STSK
DASS_TY_C_ROUTE_DIV_TBL
DAAS_HW_BOARD_S_STATE_TBL
DASS_HW_CHAN_S_STATE_TBL
DASS_AM_STATIC_TASK_TBL
UNIT
Used in commands: DUMP, LST, PATCH, SET;
unit of memory to be used
Type of Input
:
Single value, mandatory
Possible Values
:
BYTE
DWORD
WORD
Byte
Double Word
Word
VAL
Used in commands: EV, PATCH, SET;
hexadecimal value to be displayed in decimals, binary and hexadecimals (=VALue), or value to be stored at specified storage location (=VALue).
Type of Input
:
For EV:
Single value, mandatory
For PATCH, SET:
Single value, linked single values, mandatory
Possible Values
:
For EV:
Hexadecimals 0 - 7FFFFFFF
For PATCH, SET:
Hexadecimals 00 - FF,
Hexadecimals 0000 - FFFF,
Hexadecimals 00000000 - FFFFFFFF
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.