78.0.1
78.4.3 DISPLAY-DISPS
Procedure Overview
To ease up service actions, the new DISPLAY action was introduced for a quick call of DISPS data, with three options:
1. Station number
Input:
DISPLAY-DISPS:STN,<stno>;
is the equivalent of:
EXEC-DISPS:BP;
LST,SW,LODEN,STNO,<stno>,VCE;
2. Line (physical / logical) in hexadecimal
Input:
DISPLAY-DISPS:LINE,<LINE>;
is the equivalent of (LINE in decimal):
EXEC-DISPS:BP;
LST,SW,LODEN,LN,<LTG>,<LINE>;
3. Circuit
Input:
DISPLAY-DISPS:CIRC,<LTG>,<LTU>,<SLOT>,<CCT>;
is the equivalent of:
EXEC-DISPS:BP;
LST,SW,LODEN,CIR,<LTG>,<LTU>,<SLOT>,<CCT>;
Output:
H500: AMO DISPS STARTED
AMO DISPS VARIANT/VERSION 4A/001 OF 2014-03-07
DISPLAYER VARIANT/VERSION 5E/001 OF 2016-05-26
STATION NUMBER: 12100
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 0H 1H 0H 6DH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 1H 1H 0H 6EH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 2H 1H 0H 6FH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 3H 1H 0H 70H
AMO-DISPS-111 OPERATING THE DISPLAYER
DISPLAY COMPLETED;
Displaying a range of station numbers with the help of “&” or “&&”:
Input:
DISPLAY-DISPS:STN,12100&&12102;
Output:
H500: AMO DISPS STARTED
AMO DISPS VARIANT/VERSION 4A/001 OF 2014-03-07
DISPLAYER VARIANT/VERSION 5E/001 OF 2016-05-26
STATION NUMBER: 12100
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 0H 1H 0H 6DH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 1H 1H 0H 6EH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 2H 1H 0H 6FH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 3H 1H 0H 70H
STATION NUMBER: 12101
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 0H 1H 0H 71H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 1H 1H 0H 72H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 2H 1H 0H 73H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 3H 1H 0H 74H
STATION NUMBER: 12102
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 0H 1H 0H 75H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 1H 1H 0H 76H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 2H 1H 0H 77H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 3H 1H 0H 78H
AMO-DISPS-111 OPERATING THE DISPLAYER
DISPLAY COMPLETED;
Displaying a range of lines (physical / logical) in hexadecimal:
Input:
DISPLAY-DISPS:LINE,5C9&&5CB;
Output:
H500: AMO DISPS STARTED
AMO DISPS VARIANT/VERSION 4A/001 OF 2014-03-07
DISPLAYER VARIANT/VERSION 5E/001 OF 2016-05-26
STATION NUMBER: 12100
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 0H 1H 0H 6DH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 1H 1H 0H 6EH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 2H 1H 0H 6FH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 3H 1H 0H 70H
STATION NUMBER: 12101
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 0H 1H 0H 71H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 1H 1H 0H 72H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 2H 1H 0H 73H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 3H 1H 0H 74H
STATION NUMBER: 12102
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 0H 1H 0H 75H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 1H 1H 0H 76H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 2H 1H 0H 77H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 3H 1H 0H 78H
AMO-DISPS-111 OPERATING THE DISPLAYER
DISPLAY COMPLETED;
Displaying a range of circuits:
Input:
DISPLAY-DISPS:CIRC,1,1,2,0&&2;
Output:
H500: AMO DISPS STARTED
AMO DISPS VARIANT/VERSION 4A/001 OF 2014-03-07
DISPLAYER VARIANT/VERSION 5E/001 OF 2016-05-26
STATION NUMBER: 12100
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 0H 1H 0H 6DH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 1H 1H 0H 6EH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 2H 1H 0H 6FH
1T 1T 2T 2T 0T 4293T 10C5H 1481T 5C9H 3H 1H 0H 70H
STATION NUMBER: 12101
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 0H 1H 0H 71H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 1H 1H 0H 72H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 2H 1H 0H 73H
1T 1T 2T 2T 1T 4294T 10C6H 1482T 5CAH 3H 1H 0H 74H
STATION NUMBER: 12102
LTG LTU PBC/SLOT CCT L I N E PHYS_LINE SU DI/TSI SI LODEN
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 0H 1H 0H 75H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 1H 1H 0H 76H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 2H 1H 0H 77H
1T 1T 2T 2T 2T 4295T 10C7H 1483T 5CBH 3H 1H 0H 78H
AMO-DISPS-111
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.