83.3.5
EXEC-DSSU
*** not available, not supported by board SLMC ***
By means of this function CMI Basestations can be loaded and activated. The loadresult will be displayed. Activation of CMI Basestations without loading will be done by means of ACTIVATE.
Procedure Overview
Command Code
Parameter
EXEC-DSSU
[LTG=<number>],LTU=<number>,SLOT=<number>,[CIR=<number];
Examples
1.
CMI Basestation at LTG 1, LTU 1, SLOT 67, CIR 20 is to be loaded.
Input:
EXEC-DSSU:1,1,67,20;
Output:
H21: BASESTATION 1-1-67-20 LOADED
2.
CMI Basestation at LTG 1, LTU 1, SLOT 67, CIR 20 is to be loaded but failed.
Input:
EXEC-DSSU:1,1,67,20;
Output:
F48: BASESTATION 1-1-67-20 NOT LOADED, (LW-ERROR)
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.