83.4
Parameter Description
BCHL
B-channel number
Type of Input
:
Single value, && (max.2), optional
Possible Values
:
1 to 30
Default Value
:
all B-channels
CIR
Circuit number of CMI Basestation
Type of Input
:
Single value, && (max.2), optional
Possible Values
:
8 to 23
Default Value
:
all circuits of CMI Basestation
LTG
Line Trunk Group
Type of Input
:
Single value, optional
Possible Values
:
1 to 32
Default Value
:
1
Atlantic platforms allow only LTG number 1
LTU
Line Trunk Unit
Type of Input
:
Single value, required
Possible Values
:
1 up to 15
Depends on HW type
17 to 99
LTU range for IPDA AP shelves
OFFTYPE
Selection of type of deactivate job
Type of Input
:
Single value, optional
Possible Values
:
DC
Deactivate with pre- blocking
DI
Deactivate immediately
L
Long-term deactivation
Default Value
:
DC for TYPE
for TYPE = PEN / STNO
L for TYPE
for TYPE = BCHAN
DI for TYPE
for TYPE = STNO, SVC = MSN
ONTYPE
Selection of type of activate job
Type of Input
:
Single value, optional
Possible Values
:
ACL
Activation with conditional loading
AUL
Activation with unconditional loading
ANL
Activation with no loading
Default Value
:
ACL
for TYPE = PEN / STNO
ANL
for TYPE = BCHAN
ANL
for TYPE = STNO, SVC = MSN
PEN1
Port equipment number of the first or only line to be switched (LTG-LTU-SLOT-CCT)
Type of Input
:
Compound value, required
Possible Values
:
g-uu-sss-ccc
g= LTG Number
:
1 ( no other value)
uu= LTU Number
1 to 15 in HHS (Host Shelf)
17 to 99 in AP (Access Point Shelf)
16 not defined
sss= Slot
:
1 to 121 in increments of six or one depending on HW type
(See AMO
UCSU
)
ccc= Line Number
:
0 to 254
A suitable module must be configured to the slot addressed by PEN (AMO
BCSU
).
The possible LTU and Slot values for PEN depend on the systems architecture and can be found in the BCSU AMO description.
The possible Line values depend on the module type and its functionality.
They can be listed using DISP-
BCSU
: TYPE=PEN1 [,LTG=, LTU=, SLOT=, CCT=]; which will also output the actual PEN status (e.g. NOT CONNECTED).
PEN2
Port equipment number of the last line to be switched
Type of Input
:
Compound value, optional
Possible Values
:
same as for PEN1
REFOFF
Switch reference clock generator as well
Type of Input
:
Single value, optional
Possible Values
:
Y
Switch off ref. clock generator if additional available, otherwise prompt
N
Do not switch off ref. clock generator
PROMPT
Prompt if ref. clock generator found
Default Value
:
PROMPT
SLOT
Slot
Type of Input
:
Single value, required
Possible Values
:
1 to 121 in increments of six or one depending on HW type (see AMO-
UCSU
)
STNO
Station number
Type of Input
:
Single values,
chained single values (not allowed for CHANGE),
ranges (not allowed for CHANGE)
required
Possible Values
:
STNO must exist in the dialing plan
A max. of 10 values is possible, e.g. 3 ranges and 4 chained single values.
For CHANGE only single value allowed
SVC
Selection of services for configuration with terminals of different services for S0-Bus or DCI
Type of Input
:
Single value, & (max. 6)
optional
Possible Values
:
VCE
Voice
FAX
Facimile
DTE
Data terminal equipment
MSN
MSN number
ALL
All services
Default Value
:
ALL
TSI
Terminal Selection Identifier for subscribers and bus devices
Type of Input
:
Single value, optional
Possible Values
:
1 to 8
TYPE
Type of device to be switched
Type of Input
:
Single value, required
Possible Values
:
ACTIVATE/DEACTIVATE :
PEN
Port equipment number
STNO
Station number
BCHAN
B-channel of Trunk circuits
RESTART :
PEN
Port equipment number
STNO
Station number
CHANGE :
SIGNON
Sign on extension to pen
SIGNOFF
Sign off extension
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.