86.3.1
ADD-DTSM
If the device type has already been added with identical parameters, the advisory H1 is output followed by AMO EXECUTED.
A change branch is not considered necessary for this AMO. However, the user can achieve the same results using the DELETE and ADD branches.
Procedure Overview
Command Code
Parameter
ADD-DTSM
[UNIT=<param>],DEVTYPE=<param>,SIZE=<number>
,GRAN=<number>,PNO=<string>,[UNITTYPE=<number>];
Examples
1.
Add the hard disk HD001 to the database.
Input:
ADD-DTSM:,HD,3450,123,HD001,1;
2.
Add STDHD STD01 to the database.
Input:
ADD-DTSM:A1,STDHD,1221,512,STD01,2;
3.
Add FM FM001 to the database.
Input:
ADD-DTSM:,FM,1200,512,FM001,10;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.