90.4
Parameter Description
ACCT
Account number of destination computer
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
See BS2000 command language
AMOCMD
Specify an AMO-command
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
1 to
74 alphanumeric characters
FAILPROC
Command for handling of errorneous transmission
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
See DVS restrictions for filename in BS2000
FTSTT
File transfer start time
Type of Input
:
Single value
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
Hours - Minutes
Hours:
0 - 23
Minutes:
0 - 59
INIT
Initialising of LDU FAMUP
Type of Input
:
Single value
optional
(START)
Possible Values
:
Y,N
INS
System to be put in service for FAMUP
Type of Input
:
Single value
optional
(START)
Possible Values
:
Y
LINENR
Line number of AMO call
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
1 to 50
PASSWORD
Logon password of destination computer
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
See BS2000 command language
RUPINT
Interval (in days) at which a remote update is to occur
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
1 to 31
RUPSTT
Remote update start time
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
Hours - Minutes
Hours:
1 - 23
Minutes:
0 - 59
Day:
1 - 31
Month:
1 - 12
Year:
1980 - 9999
SUCCPROC
File name of proc. to be seen after a successfull transfer
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
See DVS restriction for filenames in BS2000
SCNAME
Partner computer in service center
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
All names to be formed without special characters,
1 to 8 alphanumeric characters
SEL
Selection parameter
Type of Input
:
Single value,
mandatory
(ACTIVATE, DEACTIVATE, DELETE, DISPLAY)
Possible Values
:
PARAM, AMOCMD, STATUS (DISPLAY)
ALL, AMOCMD (DELETE)
FAMUP, PROT, FTRNS (ACTIVATE, DEACTIVATE)
TYPE
Desired remote maintenance update options
Type of Input
:
Single value, mandatory
mandatory
(ADD)
Possible Values
:
LDU, AMOCMD
USERID
Logon id of destination computer
Type of Input
:
Single value,
mandatory
(ADD)
Group parameter
(CHANGE)
Possible Values
:
See BS2000 command language
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.