102.3.1
SET FUNSU
Setting the RTO
SWU and changing RTO control data.
All data concerning the RTO of the SWU (test authorization, time parameters, etc.) is stored in the static database. Each time an update job is performed this database memory is output, changed and rewritten. However, the RTO is only advised of the changes by a message sent to the interface task in the active base processor after the action EXEC has been called.
If none of the optional parameters is specified, the RTO tests will be set to default values.
It is also possible to change the RTO control data of LTGs which are out of service.
Note
The default values are obtained from basic initialization of the RTO memory.
Procedure Overview
Command Code
Parameter
SET-FUNSU
UNIT=<param>,
COMPLEX=UNIT,STARTAUT=<param>;
|COMPLEX=RJGRP,RJGRP=<param>,{[STARTAUT=<param>],
[RJSTART=<number>],[RJSTOP=<number>],
[RJPAUSE=<number>]};
|COMPLEX=RJ,RJ=<param>,RJFREQ=<number>;
Examples
1.
Issuing the start authorization for LTG1.
Input:
SET-FUNSU:GP1A,UNIT,Y;
2.
Changing the control parameters for a routine job group.
Input:
SET-FUNSU:BPA,RJGRP,RJC,Y,18,24,60;
3.
Changing the test frequency for a test job.
Input:
SET-FUNSU:GP1B,RJ,IPREQ,2;
Output:
H04: RTO OF GP1B IS NOT STARTED BECAUSE THERE IS NO FA START
AUTHORIZATION
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5