107.2.5
DISPLAY-GEZAB / REGENERATE-GEZAB
Depending on the parameters provided in the dialog command, either one specific, or all dialog fields are displayed on the dialog device. In contrast to the remaining actions provided to the user by GEZAB, not only one but several fields can be addressed in the case of parameter DIAFNO.
1.
Display of the dialog fields with output in list format (DISPLAY).
2.
Display of the dialog fields with output in position-oriented commands for the regeneration (REGENERATE).
Procedure Overview
Command Code
Parameter
DISPLAY-GEZAB
[DIAFNO=<number>];
(1)
|REGENERATE-GEZAB
[DIAFNO=<number>];
(2)
Examples
1.
Display of dialog field 2 with output in list format.
Input:
DISPLAY-GEZAB:DIAFNO=2;
Output:
DIALOG FIELD : 2 STATUS : TIMED ORDER RUNNING
FILE : CDRC1 STOP IMMED.OUTPUT : YES
HEAD OF FILE : 0004120000 DEVICE : DEV1
END OF FILE : 0004120000 FORM : FORM01
BLOCK SIZE : 50 FORCED OUTPUT : YES
DELETION : YES ABORTION : NO
START TIME : 0010011000 PERIOD : 01M
START TIME2 : START TIME 3 :
DP - CALL : NO
2.
Regenerating the timer job for dialog field 2.
Input:
REGENERATE-GEZAB:DIAFNO=2;
Output:
ADD-GEZAB:L,2,CDRC1,0004120000,0004120000,DEV1,Y,FORM01,50,Y,N,N,01M,Y;
Note:
If parameter STAT=0 (immediate output) was added with ADD-GEZAB, a regeneration will produce STAT=N. Therefore the call of this regenerated command causes no immediate output.
In addition with generating, the value of parameter FILEND is set automatically to the value of the parameter FILESTA, if the period is in the past.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.