112.2.4
DISPLAY-GRZW / REGENERATE-GRZW
1.
Interrogate the limit values for on-screen output in list form (DISPLAY)
2.
Interrogate the limit values for output in the form of a command listing for the action CHANGE-GRZW (REGENERATE)
Procedure Overview
Command Code
Parameters
DISPLAY-GRZW
[TBL=RCD]; (1)
|[TBL=CAR];
|[TBL=HOUR];
REGENERATE-GRZW
[TBL=RCD]; (2)
|[TBL=CAR];
|[TBL=HOUR];
Examples
1.
Display the limit values in list form
Input:
DISPLAY-GRZW;
Output:
LIMIT VALUES OF THE CALL DATA REGISTRATION PER ROUTING CODE
ROUTE CODE CHARGE LIMIT CONN. TIME LIMIT AMOUNT LIMIT
CODE (UNITS) (IN HH:MM:SS) (CURRENCY)
1 500 05:00:00 800
ELSE 4000 18:12:15 0
LIMIT VALUES PER CARRIER
CARRIER CHARGE LIMIT CONN. TIME LIMIT AMOUNT LIMIT
(UNITS) (IN HH:MM:SS) (CURRENCY)
0 4000 18:12:15 0
1 2000 10:30:15 100
2 4000 18:12:15 0
3 4000 18:12:15 0
4 4000 18:12:15 0
5 4000 18:12:15 0
6 4000 18:12:15 0
7 4000 18:12:15 0
8 4000 18:12:15 0
9 4000 18:12:15 0
HOUR LIMIT OF THE CALL DATA REGISTRATION (IN HH) : 5
2.
Interrogate the limit value table for regeneration
Input:
REGENERATE-GRZW;
Output:
ADD-GRZW:RCD,1,500,050000, 800;
ADD-GRZW:RCD,,4000,181215, 0;
ADD-GRZW:CAR,0,4000,181215, 0;
ADD-GRZW:CAR,1,2000,103015, 100;
ADD-GRZW:CAR,2,4000,181215, 0;
ADD-GRZW:CAR,3,4000,181215, 0;
ADD-GRZW:CAR,4,4000,181215, 0;
ADD-GRZW:CAR,5,4000,181215, 0;
ADD-GRZW:CAR,6,4000,181215, 0;
ADD-GRZW:CAR,7,4000,181215, 0;
ADD-GRZW:CAR,8,4000,181215, 0;
ADD-GRZW:CAR,9,4000,181215, 0;
ADD-GRZW:HOUR,5;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.