KDGZ - smdr/dmdr short form for call charge data output

Destination Processor: ADP

Functions

ADD password class 1
CHANGE password class 1
DELETE password class 1
DISPLAY password class 0
REGENERATE password class 2

Procedure Overview

ADD-KDGZ

ADD-KDGZ DIAFNO=<number>, FILE=<param>, FILESTA=<param>, FILEND=<param>, DEV=<param>, DEL=<param>, FORMAT=<param>, BLKSIZE=<param>, FOUT=<param>,
MULTOUT=Y,STADAY2=<param>, STADAY3=<param>, STAHR2=<param>, STAHR3=<param>, SELSTOP=<param>;
MULTOUT=N,SELSTOP=<param>;

CHANGE-KDGZ

CHANGE-KDGZ DIAFNO=<number>, {(min 1) FILE=<param>, FILESTA=<param>, FILEND=<param>, DEV=<param>, DEL=<param>, FORMAT=<param>, BLKSIZE=<param>, FOUT=<param>, MULTOUT=<param>, STADAY2=<param>, STADAY3=<param>, STAHR2=<param>, STAHR3=<param>, SELSTOP=<param>};

DELETE-KDGZ

DELETE-KDGZ DIAFNO=<number>;

DISPLAY-KDGZ

DISPLAY-KDGZ [DIAFNO=<number>];

REGENERATE-KDGZ

REGENERATE-KDGZ [DIAFNO=<number>];

Parameter description

BLKSIZE block size
Type of Input: single value, 7. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
DEL delete records
Type of Input: single value, 5. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
DEV output device
Type of Input: single value, 4. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
DIAFNO number of dialog field
Type of Input: 1 to 8 single values, concatenated with & or &&, optional (DISPLAY / REGENERATE)
single value, mandatory (ADD / CHANGE / DELETE)
Possible Values: numeric, 1-8
FILE name of file to output
Type of Input: single value, 1. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
FILEND date of file end
Type of Input: single value, 3. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
FILESTA date of file start
Type of Input: single value, 2. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
FORMAT output format/display form of application. name on digite
Type of Input: single value, 6. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
FOUT forced output
Type of Input: single value, 8. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
MULTOUT multiple output
Type of Input: single value, 9. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD)
Possible Values: N no
Y yes
SELSTOP stop immediate output
Type of Input: single value, 14. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD,MULTOUT=N-no / ADD,MULTOUT=Y-yes)
Possible Values: N no
Y yes
STADAY2 day on which to start
Type of Input: single value, 10. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD,MULTOUT=Y-yes)
Possible Values: N no
Y yes
STADAY3 day on which to start
Type of Input: single value, 11. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD,MULTOUT=Y-yes)
Possible Values: N no
Y yes
STAHR2 hour in which to start
Type of Input: single value, 12. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD,MULTOUT=Y-yes)
Possible Values: N no
Y yes
STAHR3 hour in which to start
Type of Input: single value, 13. parameter of a min-1-group (CHANGE)
single value, mandatory (ADD,MULTOUT=Y-yes)
Possible Values: N no
Y yes

Error Messages

F01
F01: SHORT DIALOG IS ALREADY ADDED
F02
F02: SHORT DIALOG IS NOT YET ADDED

Advisory Messages

H01
H01: SHORT DIALOG IS ALREADY DELETED
H02
H02: DIALOGFIELD @ IS CREATED FOR @@@. THEREFORE NO SHORT DIALOG IS POSSIBLE
H03
H03: FOR THE U.S. VERSION ARE ONLY THE DIALOGFIELDS 1 AND 2 VALID