130.4
Parameter Description
BAUD
Standardized transmission speed (baud rate)
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
50, 100, 200, 300, 600, 1200,
2400, 4800, 9600, 19200
CLK
Clock signal
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
EXT
=external
INT
=internal
LEN
Signal length (number of bits per signal)
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
5 - 7
LNTYPE
Line type
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
HDX
=HALF DUPLEX
FDX
=FULL DUPLEX
MLNTYPE
Line type (operation of synchronious lines (terminals) connected via V24 modems
Type of Input
:
Single value,
required (ADD, CHANGE)
optional (DISPLAY, DELETE)
Possible Values
:
ASYNC, V24
NORM
Standardized interface between server and line.
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
V22, V23, V24XEN, V25BIS, V25CRN, V26,
V27, V26BIS, V27BIS, V27TER, V29,
OPTYPE
Mode of operation of the interface
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
DTE (Data Terminal Equipment), if a remote line is connected to the Server via a MODEM.
DCE (Data Communication Equipment), if a data terminal device is connected (e.g. 9750) on the server (line end is simulated).
RCLK
Receiving clock
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
EXT
=external
INT
=internal
SPEED
Graduation of transmission speed for the interface specified in parameter NORM.
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
LOW, HIGH,50,100,200,300,600,1200,
2400,4800,9600,19200
STOPLEN
Stop bits length
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
SL1
=one bit
SL1.5
=1,5 bits
SL2
=two bits
TIME
Terminal runup time monitoring
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
1 - 255 sec.
TRNSCLK
Transfer clock
Type of Input
:
Single value,
required (ADD)
optional (CHANGE)
Possible Values
:
EXT
=external
INT
=internal
TYPENO
Type number, logical line number
Type of Input
:
Single value,
required (ADD, CHANGE)
optional (DISPLAY, DELETE), but can be specified only if a MLNTYPE (line type) is also specified.
Possible Values
:
for MLNTYPE=ASY :1 - 8
for MLNTYPE=V24 :1 - 14
UNIT
Processor name of the server modules to be activated
Type of Input
:
Single value,
optional
Possible Values
:
A1
= Administration and Data Server (ADS)
Default Value
:
A1
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5