143
LSSM - Switch Circuit or Line in the Server
Restrictions
Functions of the AMO
Error Messages and Advisories
Interrelationships
Parameter Description
The AMO LSSM (Line Switch of Service Modules) is used to place into service or remove from service the specified line or specified channel of a line. This requires that the hardware already be allocated and that a channel already be created.
According to the module type the physical line termination units can be assigned as following:
LCU/LBU
The first 2 line-numbers (out of 8) are valid for the 2 line termination units.
PSIO
The PSIO will not be marketed any longer.
LCR/LCS0
The following shows the sequence of the physical lines on a modul:
1. Delta-channel
no valid channel
1. B-channel of the 1. Delta-channel
2. B-channel of the 1. Delta-channel
2. Delta-channel
no valid channel
1. B-channel of the 2. Delta-channel
2. B-channel of the 2. Delta-channel
LAN
TCP - Line 1 up to TCP - Line 6 can be switched.
Messages
The messages of dependability, which are the results of a test, are not output via AMO LSSM. These messages are displayed directly on the output device of dependability.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025