145.3.6
REGENERATE-LWPAR
REGENERATE parameter blocks of a certain circuit type or all circuit types.
All 10 data blocks (0 to 9) are regenerated for TYPE=DIUS2.
All 6 data blocks (1 to 6) are regenerated for TYPE=DIUC.
For TYPE=CDG all data blocks are regenerated which deviate from the standard data base.
For analog circuit types, only those data blocks are regenerated which have been assigned to a circuit type, and of these only those block parameters are regenerated which deviate from the standard data base.
Procedure Overview
Command Code
Parameter
REGENERATE-LWPAR
[TYPE=<param>];
Example
Regenerate the parameter block 15.
Input:
REGEN-LWPAR:CDG;
Output:
CHANGE-LWPAR:CDG,15,CONF,213,,,,,,,,,,,,,,,,,,,,,,,,,,"TEST BLNO 15 CDG",,;
CHANGE-LWPAR:CDG,15,TIMER,5,,,,,,,,,,,,,,,,,,,,,;
CHANGE-LWPAR:CDG,15,MAPPING,LCOSVRRG,1&2&3&4,51&51&53&54;
CHANGE-LWPAR:CDG,15,MAPPING,TRGCBG,1&2&3&4,22&22&23&24;
CHANGE-LWPAR:CDG,15,MAPPING,DXTGITR,1&2&3&4,21&22&23&24,1,21;