146.3.2
DISPLAY-MFCTA
This function allows the user easy access to the contents of the MFC tables according to different criteria.
The parameter MFCVAR specifies the MFC tables to be displayed.
The parameter TYPE restricts the information output from the variant tables, backward and forward signal tables to the type desired.
The parameter OPT enables the user to restrict the display output to specified table types (MISC to FIDENT).
Using TYPE=HD the list of MFC initialization tables on harddisc can be displayed.
Procedure Overview
Command Code
Parameter
DISPLAY-MFCTA
[MFCVAR=<number>],
[TYPE=MFCVAR],[OPT=MISC|SUPERV];
|[TYPE=TBLB],[OPT=FSIG|FORIB|FORIA|FIDENT|BSIGA
|BSIGB|BSIGB1|BIDENT|EVAL];
|[TYPE=TBLF],[OPT=BSIGA|BSIGB|BSIGB1|BIDENT
|BSIG2|FIDENT];
|[TYPE=ALL];
|[TYPE=HD];
Note:
Default value is TYPE=ALL.
Examples:
1.
Display diverse data
Input:
DISPLAY-MFCTA:MFCVAR=2&3,TYPE=MFCVAR,OPT=MISC;
2.
Display the supervision time of the evaluation
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=MFCVAR,OPT=SUPERV;
3.
Display the table ’Group I signal on dialing’
(MFC signal conversion table for BACKWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=3,TYPE=TBLB,OPT=FSIG;
4.
Display the table ’Group II signal after A3’
(MFC signal conversion table for BACKWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLB,OPT=FORIB;
Descriptions for the output of the table with OPT = FORIB
N
=
NOPO
Not possible; an error will be output.
S
=
SIG
Apply the backward signal from group B assigned to the dialing result in the BSIGB table.
E
=
EVAL
Refer to the appropriate EVAL table (0..3).
C
=
COEX
Class of externals
5.
Display the table ’Group II signal after A5’
(MFC signal conversion table for BACKWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLB,OPT=FORIA;
6.
Display the table ’Group I signal on ID check’
(MFC signal conversion table for BACKWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLB,OPT=FIDENT;
7.
Display the table ’Group A signal on dialing’
(MFC signal conversion table for BACKWARD mode, OPT=BSIGA)
The output tables for OPT=BSIGB/BSIGB1/BIDENT have the same output format as for OPT=BSIGA.
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLB,OPT=BSIGA;
8.
Display the table ’Evaluation table’
(MFC signal conversion table for BACKWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLB,OPT=EVAL;
9.
Display the table ’Group A signal on dialing’
(MFC signal conversion table for FORWARD mode, OPT=BSIGA)
The output tables for OPT=BSIGB/BSIGB1/BIDENT have the same output format as for OPT=BSIGA.
Input:
DISPLAY-MFCTA:MFCVAR=2,TYPE=TBLF,OPT=BSIGA;
10.
Display the table ’Back. group II signal on transition to B signal’
(MFC signal conversion table for FORWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLF,OPT=BSIG2;
11.
Display the table ’Significance on ID check’
(MFC signal conversion table for FORWARD mode)
Input:
DISPLAY-MFCTA:MFCVAR=1,TYPE=TBLF,OPT=FIDENT;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.