146.3.3
REGENERATE-MFCTA
The REGENERATE action compares the contents of the MFC tables with those of the basic initialization tables on the hard disk, and outputs any discrepancies in the form of position-oriented commands for regenerating.
Thus, if the basic initialization table MFCVARI was copied from the hard disk into the MFCVAR table, the COPY command will be output, as will any CHANGE commands carried out since generating.
The parameter MFCVAR specifies the MFC tables to be displayed.
The parameter TYPE restricts the information output from the variant tables, backward and forward signal tables to the type desired.
The parameter OPT enables the user to restrict the display output to specified table types (MISC to FIDENT).
Procedure Overview
Command Code
Parameter
REGENERATE-MFCTA
[MFCVAR=<number>],
TYPE=MFCVAR,[OPT=MISC|SUPERV];
|TYPE=TBLB,[OPT=FSIG|FORIB|FORIA|FIDENT|BSIGA|
,|BSIGB|BSIGB1|BIDENT|EVAL];
|TYPE=TBLF,[OPT=BSIGA|BSIGB|BSIGB1|BIDENT
|BSIG2|FIDENT];
|[TYPE=ALL];
Note:
Default value is TYPE=ALL.
Example:
Regenerate miscellaneous data (MFC variant table)
Input:
REGENERATE-MFCTA:MFCVAR=2,TYPE=MFCVAR,OPT=MISC;
Output:
COPY-MFCTA: 1,2;
CHANGE-MFCTA:2,MFCVAR,MISC,SOCFB,SOCFF,10,RSV1&RSV2&RSV3,N,,N,,N,,Y,2ABD0;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.