146.4
Parameter Description
ADINFO
Additional information
Type of Input
:
Single value, optional
Possible Values
:
0 - 99
1 - 16 for STNCAT=INFO
Default Value
0
ADREQ
Address request/retransmit signal(s)
Number of request signals and request signals for SOCOTEL
The CCITT-R2 standard allows the dialed number to be repeated with this code once the MFC signal exchange has begun (request last or penultimate signal from the central office/exchange).
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - F, *, #, of max. 6 digits
For SOCOTEL (MFCTYPB/MFCTYPF=SOCFB/SOCEB/SOCFF/SOCEF),
at least 1 request signal must be set.
ANBEG
Begin position of A number in CPB
Type of Input
:
Single value, optional
Possible Values
:
0 - 44
Default Value
:
0
Type of Input
:
Single value, optional
ANEND
End position of A number in CPB
Position for insertion of A number
Type of Input
:
Single value, optional
Possible Values
:
0 - 44
Default Value
:
0
ANICAT
Ani category
Type of input
single value, optional
Possible values:
ANI1 ani kategorie 1 DB_MFC_ANI1
ANI10 ani kategorie 10 DB_MFC_ANI10
ANI2 ani kategorie 2 DB_MFC_ANI2
ANI3 ani kategorie 3 DB_MFC_ANI3
ANI4 ani kategorie 4 DB_MFC_ANI4
ANI5 ani kategorie 5 DB_MFC_ANI5
ANI6 ani kategorie 6 DB_MFC_ANI6
ANI7 ani kategorie 7 DB_MFC_ANI7
ANI8 ani kategorie 8 DB_MFC_ANI8
ANI9 ani kategorie 9 DB_MFC_ANI9
NULL no evaluation DB_MFC_NULL
APOS
Position for insertion of A number
Type of Input
:
Single value, 11. parameter of a min-1-group
Possible Values
:
0 - 44
Default Value
:
0
BACKTYPE
MFC conversion tables, backward signals
Type of Input
:
Single value, optional
Possible Values
:
ANIBACKW
ani backward
ANIFORW
ani forward
MFPBACKW
mfp backw co -> system
MFPFORW
MFP mode forward system -> co
MFRPB
multi frequency packed backward
MFRPF
multi frequency packed forward
MFRSB
multi frequency shuttle backward
MFRSF
multi frequency shuttle forward
NULL
no evaluation
R1
ccitt-r1 mode
R2BKWD
Operation on CCITT-R2 mode
CCITT-R2 standard operation
PABX=terminal exchange
Transmitter: Forward
R2FORW
Operation on CCITT-R2 mode
PABX=origin
Transmitter: Forward
Receiver : Backward
SOCE6B
MFC SOCOTEL forward mode, Spain
(CO sends dial signals to PABX)
Transmitter: Control freq. (2 out of 6)
Receiver : MFC signals
SOCE6F
MFC SOCOTEL forward mode, Spain
(CO sends dial signals to PABX)
Transmitter: MFC signals
Receiver : Control freq. (2 out of 6)
SOCEB
MFC SOCOTEL (2 out of 5), Spain backward
(PABX sends dial signals to CO)
Transmitter: MFC signals (2 out of 5)
Receiver : Control frequency
SOCEF
MFC SOCOTEL forward mode, Spain
(CO sends dial signals to PABX)
Transmitter: MFC signals
Receiver : Control freq. (2 out of 5)
SOCFB
MFC SOCOTEL (2 out of 6), France
backward (PABX sends dial signals to CO)
Transmitter: MFC signals (2 out of 6)
Receiver : Control frequency
SOCFF
MFC SOCOTEL forward mode, France
(CO sends dial signals to PABX)
Transmitter: MFC signals
Receiver : Control freq. (2 out of 6)
BSDIRCNT
length of basic directory number
Type of Input:
single value, optional
Possible Values:
numeric, 0-22
BSDIRNO
basic directory number
Type of Input:
single value, optional
Possible Values:
0-9,*,#,A-D, up to 22 characters
BSIG
Backward signal to be transmitted
Type of Input
:
Single value, optional
Possible Values
:
0 - 15
IF BSIG = 0 in the table BSIGA for BACKTYPE = R2BKWD, then no BSIG will be send to CO.
For SOCOTEL BSIG = 0 is interpreted as control frequency.
CATEGORY
Physical grp II signal to be transmitted (on identification)
Type of Input
:
Single Value, optional
Possible Values
:
0 - 15
CATTRANS
station category in case of transit
Type of Input:
single value, optional
Possible Values:
A-K
ATND
attendant console
ATND1
attendant console 1
ATND2
attendant console 2
DATA
data transfer
DATA1
data transfer 1
DATA2
data transfer 2
DATANTLL
data no toll
FWDCO
call forwarding to central office (co)
IGNFWD
ignore call forwarding
INFO
info
LOCLCALL
local call
NOMEAN
no meaning
NOMENTLL
no meaning, no toll
PRIO
with priority
PRIO1
with priority 1
PRIO2
with priority 2
PRIONTLL
priority, no toll
SATELLIT
sattelite
TESTEQ
test equipment
TOLLCALL
toll call
TRANSIT
transit
CHADGT
Change digits (Y/N)?
Type of Input
:
Single value, mandatory
Possible Values
:
N,NO
[no],no, criterion for req. sig./digit entry changes
Y,YES
[yes],yes, criterion for req. sig./digit entry changes
CHAREQ
Change request signal(s)
Type of Input
:
Single value, mandatory
Possible Values
:
N,NO
[no], no, criterion for req. sig./digit entry changes
Y,YES
[yes], yes, criterion for req. sig./digit entry changes
CHEXAC
Change exchange access code for identification (Y/N)?
Type of Input
:
Single value, mandatory
Possible Values
:
N,NO
[no], no digits to be changed. If there is a value entered for the succeding parameter EXACFI this value is ignored.
Y,YES
[yes], digits are to be changed according tor the parameter EXACFI; if nothing is specified number of digits and the digits themselves will be set to 0.
CHLCLTR
Change local trunc code (Y/N)?
Type of Input
:
Single value, mandatory
Possible Values
:
N,NO
[no], no digits to be changed. If there is a value entered for the succeding parameter LCLTRCD this value is ignored.
Y ,YES
[yes], digits are to be changed according tor the parameter LCLTRCD; if nothing is specified LCLTRCD will be deleted.
CHTRDIS
Change traffic discrimation digit for identification (Y/N)?
Type of Input
:
Single value, mandatory
Possible Values
:
N,NO
[no], no digits to be changed. If there is a value entered for the succeding parameter TRDISDI this value is ignored.
Y,YES
[yes], digits are to be changed according tor the parameter TRDISDI; if nothing is specified the TRDISDI will be deleted.
CNT
Number of valid postions on the ID sequence
Type of Input
:
Single value, optional
Possible Values
:
0 - 22
Default Value
:
Number of specified hexadecimal digits of the parameter ID
If CNT is less than the number of characters specified with ID, then only the value entered for CNT is taken into account.
If CNT is greater than the number of characters specified with ID, then the value entered for ID is boosted by adding zeroes (’0’) to the hexadecimal number.
If CNT=0, ID is deleted.
COEX
Class of external
Type of Input
:
Single value, optional
Possible Values
:
0 - 16
COEXTRAN
Class of external in case of transit
Type of Input
:
Single value, optional
Possible Values
:
0 - 12
CTLF
Supervision time for control frequency (removal)
Only used for SOCOTEL (BACKTYPE/FORWTYPE=SOCFB/SOCEB/SOCFF/SOCEF)
Type of Input
:
Single value, optional
Possible Values
:
0-999999
0 = Deactivate supervision
DGTS
Evaluation table digit(s)
Number of digits + digits of an evaluation table
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - F, of max 6 hexadecimal digits
No input is interpreted as meaning no digits.
(Number of digits and the digits themselves will be set to 0.)
DIGIT
mfc-signal see CCITT Q.441
Type of Input:
single value, optional
Possible Values:
numeric, 0-15
DINFO
Dialing Information
Type of Input
:
Single value, optional
Possible Values :
ADINFO
Additional information (reserved)
ANO
Transfer to A-party number
DGT
Transfer dialed digits
IDEND
End of A-party number transfer
IDREF
Send A-party number request refused
IDSEND
Send A-party number
INCO
Dialing incomplete
NOPO
Not possible
NULL
No evaluation
TRACE
Malicious call trace
EODTYPE
End-of-dial signal type (digit analysis result)
Type of Input
1 to 20 single values, concatenated with &, mandatory
Possible Values
ADVICE
station returning advisory / recorded info
BSYCO
Device busy on CO call
BSYTIE
Device busy on tie/house call
BUSY
Device busy
CONG
Congestion / exchange busy
DIDDND
station has do not disturb for indial
DND
Do not disturb is active
STNCL
station/subscriber class
ETEMIN1
End to End, repeat second last digit (n-1)
ETEMIN2
End to End, repeat second last digit (n-2)
ETEMIN3
End to End, repeat second last digit (n-3)
ETEMINX
End to End, repeat all digits
ETENORSP
End to End, no backward signal
FRCHG
Device free, call charges
FRNCHG
Device free, no call charges
IDENT
Changeover to identity check state
INCO
Dialing incomplete
MCIDFC
subscriber call tracing and free of charge
NASS
Call fwd. LODEN / station no. LODEN not assigned)
NAUTH
Connection does not have required authorization
NAVA
Not available (finding or hunt restrictions)
NOPO
Not possible
NVAL
Not valid
OVR
override busy station
TEST
Connection to test circuit
TRACE
Malicious call trace
TRANS
Through-connection (transit) to ATND console
EVTBL
Pointer to MFC evaluation tables
Type of Input
:
Single value, mandatory
Possible Values
:
0 - 3
EXACFI
Exchange access code for identification
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - D, *, #, of max. 6 digits
FILLCHAR
fill character at minimal digit position
Type of Input:
single value, optional
Possible Values:
hexadecimal, up to 1 characters
FORWTYPE
MFC conversion tables, forward signals
(see parameter BACKTYPE for description)
FSIG2
Group state for forward signal
Type of Input
1 to 23 single values, concatenated with &, mandatory
Possible Values
ANI1-10
ani kategorie 1-10
AXINT
Call extension by ATND with intervention/announcement
AXNOI
call extention by atnd without intervention/ann.
AXRLS
Call extension by ATND with speed release
COIN
Coin
DATA
Data transmission
DATANTLL
data connection, no toll
FWDCO
Forwarding to CO
INATC
International call
INATCLPR
internation call into private network
INFO
Reference to ADINFO
LOC
Local-Call
LOCCLPR
local call into private network
LOCNV
Local-Data-Call
LOCS
Local service
NATC
National call
NATCLPR
national call into private network
NATS
National service
NOPO
Not possible
PRISTN
Priority station or CO subscriber
SATCONN
satellite connection
STN
Station
STNCAT1
Reserved
STNCAT2
Reserved
STNCAT3
Reserved
STNNTLL
station no toll
STNPRONT
station with priority, no toll
STPRIO1
Station/subscriber with prio 1
TEST
Connection to test circuit
TOLLC
Toll-Call
TOLLOP
Toll operator
ROUTINE
MLPP routine call
PRTY
MLPP priority call
IMMED
MLPP immediate call
FLASH
MLPP flash call
FLASHOV
MLPP flash override call
PROT
MLPP protected call
ID
Identification signal sequence
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - F, of max. 22 hexadecimal digits
MFC signal sequence of 1 - 22 hexadecimal digits
Default Value
:
blank signal sequence
IDX
iIndex to evaluation table
Type of Input
:
Single value, optional
Possible Values
:
0 - 3
Evaluation table 0 to 3
4
Toll call
5
Local call
6 - 99
Preliminaries
Default Value
:
0
IMP
Revert to impulsing on error (MFC R2)
If BACKTYPE/FORWTYPE=SOCFB/SOCEB this parameter is of no significance
Type of Input
:
Single value, optional
Possible Values
:
0 - 15
IMP2
Error with call forwarding to attendant
Type of Input
:
Single value, optional
Possible Values
:
0 - 15
IMPD
Duration of "IMP" pulse
Only used for BACKTYPE/FORWTYPE=R2BKWD.
If BACKYPE/FORWTYPE=SOCFB/SOCEB/SOCFF/SOCEF, this parameter is of no significance.
Type of Input
:
Single value, optional
Possible Values
numeric, 0-999999
IMPS
Seperation of MFC "IMP" pulse
Only used for BACKTYPE/FORWTYPE=R2BKWD.
If BACKYPE/FORWTYPE=SOCFB/SOCEB/SOCFF/SOCEF, this parameter is of no significance.
Type of Input
:
Single value, optional
Possible Values
:
numeric, 0-999999
INFO
Additional information to aid programming
Type of Input
:
Single value, optional
Possible Values
BSIG
End signal exchange, changeover to B signal
:
DIAL
Dialing incomplete
END
End exchange of signals
IDENT
Changeover to identity check state
INFOA
Reserved
INFOB
Reserved
INFOC
Reserved
LCLTRCD
Local trunc code
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - D, *, #, of max. 6 digits
MAXDGTS
maximum number of a-digits from CO
Type of Input:
single value, optional
Possible Values:
numeric, 0-22
MFCVAR
MFC table
Type of Input
:
1 to 3 single values, concatenated with & or &&, mandatory (CHANGE)
1 to 3 single values, concatenated with & or &&, optional (DISPLAY / REGENERATE)
single value, optional (COPY)
Possible Values
:
numeric, 1-10
MFCVARI
Number of MFC table to COPY
Type of Input
:
Single value, mandatory
Possible Values
:
0 - 255
MFPPAUSE
Pause duration for MFP signaling (5ms steps)
Type of Input
:
Single value,optional
Possible Values
:
0 -1270 ms
MFPPULS
Pulse duration for MFP mode (5ms steps)
Type of Input
:
Single value, optional
Possible Values
:
0 -1270 ms
NEXTSIG
Supervision time for next signal, forward mode
Type of Input
:
Single value, optional
Possible Values
numeric, 0-999999
NXTSIG
Supervision time for next signal
Type of Input
:
Single value, optional
Possible Values
numeric, 0-999999
OPT
Branch parameter, MFC table option
Type of Input for DISPLAY,TYPE=MFCVAR / REGENERATE,TYPE=MFCVAR
1 to 2 single values, concatenated with &, optional
Type of Input for
DISPLAY,TYPE=TBLF / REGENERATE,TYPE=TBLF
1 to 7 single values, concatenated with &, optional
Type of Input for DISPLAY,TYPE=TBLB / REGENERATE,TYPE=TBLB
1 to 9 single values, concatenated with &, optional
Type of Input for CHANGE,TYPE=MFCVAR / CHANGE,TYPE=TBLB / CHANGE,TYPE=TBLF
single value, mandatory
Possible Values for TYPE=TBLB (backward mode):
BIDENT
Back. group A signal in origin
BSIGA
Back. group A signal on dialing
BSIGB
Back. group B signal on dialing
BSIGB1
2nd Group B signal table
EVAL
Evaluation tables
FIDENT
Group I signal on ID check
FORIA
Group II signal after A5
FORIB
Group II signal after A3
FSIG
Group I signal on dialing
Possible Values for TYPE=TBLF (forward mode):
BIDENT
Group A signal on ID check
BSIGA
Group A signal on dialing
BSIGB
Group B signal on transition to grp II
BSIGB1
2nd group B signal table
BSIG2
Back grp II sig on transition to B sig
DIALOUT
Evaluation of digits to send
FIDENT
Back. significance on ID check
Possible Values for TYPE=MFCVAR
MFCVAR
miscellaneous data for a specified variant
SUPERV
supervision parameters for evaluation
ORIG
Originating party signal handling option
Type of Input
:
Single value, single value, optional
Possible Values
:
COEX
Class of externals
EVAL
Evaluation of dialed number,
NOPO
Not possible (error listing is output)
SIG
apply the backward signal from group b
PABXID
PABX identification sequence
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - F, of max. 22 hexadecimal digits
MFC signal sequence of 1 - 22 hexadecimal digits
Default Value
:
blank signal sequence
PAR
Parameters (attributes) for MFC variant
Type of Input
:
1 to 17 single values, concatenated with &, optional
Possible Values
AMTC2
Electro mechanical exchange of type C2
AMTC3
Electro mechanical exchange of type C3
CATTOID
change category to identifier
CHKIDDGT
check first digit at ident
CHRGSIM
activate call charging simulateion
EOFSEL
send dialing end to lw
FRELBU
forward release if busy
FRELSB
forward release if station busy
IDBEFBS
identify before b station
IDCAT
Station/subscriber category number transfer.
IDNOCAT
identification without station/sub. category
IGNI15
ignore i-15 as first sign
KATTOA
category is part of A number
MFCMO
mfc monitoring message for test
MFRP3
mfr-packet protocol 3
MFRPE
mfr-packet with echo blocking
MFRPRES
reserved parameter 1 for MFRP
NOB11
no B11-Signal at incoming long distance seizure
NOMFCMO
supress mfc monitoring message
NONE
No attribute
NONE is used to delete resp. override values of the parameter PAR. If NONE is used in combination with other values, only the values after NONE will be accepted.
NOTNER
Backward release on error without alerting tones or MFC register signals (e.g. as for Belgium).
PRIOSUB
subscriber with override authorization
RSV1
Reserve attribute 1 for diverse country-specific adaptations.
RSV2
Reserve attribute 2 for diverse country-specific adaptations.
RSV3
Reserve attribute 3 for diverse country-specific adaptations.
RSV4
Reserve attribute 4 for diverse country-specific adaptations.
RSV5
Reserve attribute 5 for diverse xcountry-specific adaptations.
SOCEBWS
extended backwardsignal (socotel)
SOCTEST
exchange simulation ibercom,mfc-socotel (spain)
SPCMA
Programmable exchange of type SPC with A number
SPCOA
Programmable exchange of type SPC w/o A number
TRANSWB
without b-signal at transit if b-number available
WBEOAAN
wait between end of address and answer
TSTSTATE
activate test states
MLPP
Multi-Level Precedence and Preemption Service
PCNT
Number of valid position in the PABX ID
Type of Input
:
Single value, optional
Possible Values
:
0 - 22
Default Value
:
Number of specified hexadecimal digits of the parameter PABXID
If PCNT is less than the number of characters specified with PABXID, then only the value entered for PCNT is taken into account.
If PCNT is greater than the number of characters specified with PABXID, then the value entered for ID is boosted by adding zeroes (’0’) to the hexadecimal number.
If PCNT=0, ID is deleted.
PHYSIG
Supervision physical forward signal
Grp I forward signal on dialing (TYPE=TBLB, OPT=FSIG)
Grp I forward signal, significance after A5 (TYPE=TBLB, OPT=FORIA)
Grp I forward signal on ID check (TYPE=TBLB, OPT=FIDENT)
Grp II forward signal, significance after A3 (TYPE=TBLB, OPT=FORIB)
Type of Input
:
Single value, concatenated single values(max.16)
optional (for TYPE=TBLF, OPT=BSIG2)
mandatory (else)
Possible Values
:
0 - 15
POS1
Position for the insertion of various id sig. blocks, e.g. PABXID
POS2
Position for the insertion of various id sig. blocks, e.g. PABXID
POS3
Position for the insertion of various id sig. blocks, e.g. PABXID
POS4
Position for the insertion of various id sig. blocks, e.g. PABXID
Type of Input
:
Single value, optional
Possible Values
:
0 - 22
Default Value
:
0
RMVCTL
Supervision time for control frequency removal
Only used for SOCOTEL (BACKTYPE/FORWTYPE=SOCFB/SOCEB/SOCFF/SOCEF)
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
0 = Deactivate supervision
RMVSIG
Supervision time for removal of forward signal
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
0 = Deactivate supervision
SIG
Logical significance of an MFC signal (on dialing)
For SOCOTEL (BACKTYPE/FORWTYPE=SOCFB/SOCEB/SOCFF/SOCEF) only the values SIG = DGT0 - DGT15 may be allowed for the forward signal (not verified by the AMO)
Type of Input
:
Single value, mandatory
Possible Values
:
DGT0 - DGT15
Number of called station
REJ
Request rejected i.e information requested is not available
EOD
End of dialing / pulsing or end of identification
NOPO
Not possible
EVAL
Evaluation of dialed number pointer to evaluation table (parameter IDX)
GR2
group II signal
IDALLWD
ident allowed
SIGLENF
Signal duration (length) in forward mode
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
0 = Deactivate supervision
SIGN
Backward signal name
Type of Input
:
Single value, mandatory
Possible Values
:
INCO
Dialing incomplete
MIN1
Repeat second last digit (N - 1)
MIN2
Repeat third last digit (N - 2)
MIN3
Repeat fourth last digit (N - 3)
RPTALL
Repeat all digits from beginning
BSIG
End signal exchange, change to B sig
BUSY
Station busy
BSYINT
Station busy on internal call
BSYCO
Station busy on CO call
BSYLCL
Station busy on local call
BSYTOLL
Station busy on toll call
CONG
Congestion / exchange busy
STNCL
Station/subscriber class
IDENT
Send station number of A station
TRACE
Start malicious call trace
NOTERM
No terminal connection
NEWNO
Number changed
FRCHG
Station free, call charges
FRNCHG
Satatio free, no call chanrges
FAULT
Station or station port fault
OLDSTN
Previous station/subscriber
NOPO
Not possible
NVAL
Not valid
NOT
Send notification tone
FPTYC
First Party Control
CPTYC
Calling Party Control
BSYNOVR
No override at busy station
BSIGN2
B-signal (reserved)
BSIGN3
B-signal (reserved)
GRADIG
Send digits group ’a’
GRCDIG
Send digits group ’c’
ALLDIG
Send all digits
CALLCLS
Send call class
SLEN1
extended send time 1
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
SLEN2
extended send time 2
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
SPAU
Pause duration until send of next signal
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
STADIAL
Supervision time for first signal i.e. start dial supervision
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
0 = Deactivate supervision
STNCAT
Station/subscriber category
Type of Input
:
Single value, optional
Possible Values
:
STN
Station
PRISTN
Priority station or CO subscriber
ANI1-10
ani kategorie 1-10
DATA
Data transfer
AXRLS
Call extention by ATND with speed rel.
TOLL
Toll Call
LOC
Local Call
LOCNV
Local Data Call (non-voice)
LOCCLPR
local call to private network
TEST
Connection to test circuit
COIN
Coin
AXINT
Call ext. by ATND with intervention/ann
AXNOI
Call ext. by ATND without intervention/announcement
STPRIO1
Station/subscriber with priority 1
TOLLOP
Toll operator
FWDCO
Forwarding to CO
INFO
Reference to additional information
NOPO
Not possible
STNCAT1
Reserved
STNCAT2
Reserved
STNCAT3
Reserved
STNNTLL
station no toll
STNPRONT
station with priority, no toll
DATANTLL
data connection no toll
NATCLPR
national call into private network
INATCLPR
international call into private network
SATCONN
satellite connection
ROUTINE
MLPP routine call
PRTY
MLPP priority call
IMMED
MLPP immediate call
FLASH
MLPP flash call
FLASHOV
MLPP flash override call
PROT
MLPP protected call
TNSIG
Supervision time for event: Tone signal present
Type of Input
:
Single value, optional
Possible Values
:
0 - 999999 milliseconds
0 = Deactivate supervision
TRDISDI
Traffic discrination digit for identification
Type of Input
:
Single value, optional
Possible Values
:
0 - 9, A - D, *, #, of max. 6 digits
TYPE
Branch parameter
Type of Input
:
Single value
mandatory (CHANGE)
optional (DISPLAY, REGENERATE)
Possible Values
:
MFCVAR
MFC variant table
TBLB
MFC conversion table, backward signals
TBLF
MFC conversion table, forward signals
ALL
Output all MFC information (DISPLAY and REGENERATE)
HD
Display a list of all existion MFC initialization tables on harddisk (only DISPLAY)
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.