147.4
Parameter Description
ATNDGR
ATND group number of internal centralized ATND service
Type of Input
:
single value, mandatory
Possible Values
:
0 - 15
AMO NAVAR does not verify, whether the ATNDGR has already been assigned by AMO
VFGR
.
CD
Code for external centralized ATND service
Type of Input
:
single value, mandatory
Possible Values
:
1 - 22 digits long
AMO NAVAR does not verify, whether the CD has already been assigned by AMO
VFGKZ
.
FUNCT
Whether devices are to be added or removed
Type of Input
:
single value, mandatory
Possible Values
:
DEL
= delete device
ADD
= add device
GENANSNO
Device number of preassigned universal night answer station
Type of Input
:
single value, mandatory
Possible Values
:
0 to 15
NOPTNO
Number of the night switch option
Type of Input
:
single value,
concatenated single values, range (except ADD)
optional (CHANGE, DISLPAY, REGENERATE)
mandatory (ADD, DELETE)
Possible Values
:
1-128
Default Value
:
1&&128
STNO
Station number
Type of Input
:
single value, concatenated single values
mandatory
Possible Values
:
DNs of created stations. In total, no more than 10 stations may be allocated to an option.
TYPE
Night answer category
Type of Input
:
single value, mandatory
Possible Values
:
NONE
dummy option
STN
station option
GENANS
general answering from any station option (universal night answer)
CASINT
internal centralized ATND service group
CASEXT
external centralized ATND service group
Note
:
It is not possible to assign SET600 devices (see AMO
SBCSU
) to a night option of TYPE=STN (F10 will be output).
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.