151
PETRA - Tracer Control via AMO
Interrelationships
Parameter Description
AMO Functions
Error Messages and Advisories
The AMO PETRA can be used to create, interrogate and stop trace procedures in circuits on peripheral modules of the SWU. Furthermore, memory contents can be displayed on these modules.
All received data can be displayed on the service terminal in its entirety or in part.
The periphery (PP) of an LTG collects these data, divided according to TRACE and DUMP values, in one memory segment each. Upon request by the AMO, PP forwards this data to the AMO.
The TRACE data can then be displayed entirely or in part as often as required using AMO PETRA. The DUMP data, on the other hand, are passed on directly to the terminal by the AMO.
Most peripheral modules can be operated with AMO PETRA.
If an attempt is made to activate the loadware TRACER in an untraceable module, the input is acknowledged by the AMO with the error message "F05: BOARD HAS NO PERIPHERAL TRACER". (Using the addressing specified, the module type is determined and compared with the value in the UBGDAT)
The same applies for the DUMP also.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.