151.2.1.2
Trace processes on special modules (HEX)
On some modules (e.g. CMI) the trace process is activated with longer commands. This is possible with the branch HEX. 64 Byte in one command are possible.
The parameter LENGTH shows the number of HEX-Values. The parameter CCT is not estimated by all modules (you must not use this parameter in relation with the module CMI).
Procedure Overview
Kommandocode
Parameter
ADD-PETRA
TYPE=HEX,[LTG=<number>],LTU=<number>,SLOT=<number>
,[CCT=<number>],LENGTH=<number>,[HEX01=<number>]
,[HEX02=<number>]....[HEX64=<number>];
Example
The module is waiting for the command A157BD300F.
Input:
ADD-PETRA:HEX,,2,43,,5,A1,57,BD,30,0F;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.