151.3
Parameter Description
ADR
Address of DUMP
Type of Input
:
Single value, mandatory
Possible Values
:
0 to FFFF
BYTE1
Type of Input
:
Single value, mandatory
Possible Values
:
0 to FF
BYTE2
Type of Input
:
Single value, mandatory
Possible Values
:
0 to FF
CCT
Circuit number of a module
Type of Input
:
Single value, mandatory
Possible Values
:
0 to 63
CONT
Switch for ending the AMO
Type of Input
:
Single value, optional
Possible Values
:
Y
the AMO will not be ended
:
N
the AMO will be ended
Default Value
:
Y
CPU
CPU type
Type of Input
:
Single value, mandatory
Possible Values
:
86
for 8086
51
for 8051
MM
for MAIN MICRO on a LTUR module
IMF
for IMF/DFE on a LTUR module
HDLC
for HDLC processor on a LTUR module
HEX01
1. Byte of trace job
Type of input:
Single Value, mandatory
Possible Values
0 bis FF
Default Value
0
HEX02
2. Byte of trace job
Type of input:
Single Value, mandatory
Possible Values
0 bis FF
Default Value
0
HEX64
64. Byte of trace job
Type of input:
Single Value, mandatory
Possible Values
0 bis FF
Default Value
0
LENGTH
Number of Trace jobs
Type of Input
:
Single Value, mandatory
Possible Values
:
1 to 64
LTG
Number of the line trunk group
Type of Input
:
Single value, optional
Possible Values
:
1 to 32
Default Value
:
1 (for Hicom 370)
LTU
Number of the line trunk unit
Type of Input
:
Single value, mandatory
Possible Values
:
1-15 and 17-99
NO
Length in bytes of the DUMP area to be output for DISPLAY or
number of the TRACE data to be output for OUTPUT
Type of Input
:
Single value, optional
Possible Values
:
0 to 8154
in DISPLAY
0 to 1024
in OUTPUT
Default Value
:
8154
in DISPLAY
1024
in OUTPUT
PROC1
Receive processes to be logged unless on
Input Type
:
Single value, linked single value or range of values,
mandatory
Possible Values
:
0 to F
PROC2
Send processes to be logged unless on
Input Type
:
Single value, linked single value or range of values,
mandatory
Possible Values
:
0 to F
Default Values
:
no process
SEG
Hexadecimal segment value for dump address on 8086 and ROLM
modules (for MM, IMF or HDLC)
Type of Input
:
Single Value, mandatory
Possible Values
:
0 to FFFF
SEG1
Symbolic segment specification for 8051
Type of Input
:
Single value, mandatory
Possible Values
:
CSEG
code segment
DSEG
data segment
XSEG
extra segment
SLOT
Specification of the slot in the LTU
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 121
A suitable module must be configured for the slot addressed by PEN (AMO
BCSU
).
The possible Slot values depend on the systems architecture and can be found in the BCSU AMO description.
TYPE
Type of display, Type of module
Type of Input
:
Single Value, mandatory in ADD, optional in DISPLAY
Possible Values in the branch DISPLAY:
TRACE
retrieveTRACE-Memory (Default value)
DUMP
retrieve and output DUMP memory
Possible Values in the branch ADD:
STD (Standard module)
HEX (Trace job in HEX format)
LTUR (LTUR-module)
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.