153.5
Parameter description
BOARD
Module type for determination of class of table
Type of input
:
Single value
mandatory (CHANGE)
optional (CHANGE,REGENERATE)
Possible Values
:
LEVEL = BOARD
CDG DIUC DIUC64 DIUN2 DIUN4 DIU2U
DIUS2 NCUI SLMB16 SLMC SLMO
SLMQ SLMS SLMU16 SLMY STHC
STMA2T STMAS STMI STMIHFA STMIIGW STMI2IGW TMDN VCM
WAML1 WAML2 OTHER
LEVEL = BOARD1
DIUC DIUC64
LEVEL = BOARD2
DIUC64
The value OTHER is not valid for the actions CHANGE and REGENERATE.
COUNTACT
Counter action
Action on reaching counter limit
Type of Input
:
Single value, optional
Possible Values
:
0
Counter remains unchanged
2 to 254
Reset by n
(only even values permitted)
255
Reset to 0
CPTYPE
CP device type
Type of Input
:
Single value, linked single values,
ranges, up to 12 values, hexadecimal,
optional
Possible Values
:
0 to 48
Default value
:
all device types
DECREM
Decrement
Decrement on reaching the interval defined with TIME
Type of Input
:
Single value, optional
Possible Values
:
0
Counter remains unchanged
2 to 254
Reset by n
(only even values permitted)
255
Reset to 0
DHTYPE
DH device type
Type of Input
:
Single value, linked single values,
ranges, up to 12 values, hexadecimal,
optional
Possible Values
:
0 to 5A
Default value
:
all device types
ERROR
Class of errors where the command is effective
Type of Input
:
1 to 12 single values, concatenated with &,optional (DISPLAY, TYPE=VECO)
1 to 13 single values, concatenated with &,optional (CHANGE, TYPE=VECOLEVL / VECOSWCH)
1 to 4 single values, concatenated with &,optional (REGENERATE, TYPE=VECO)
Possible Values
:
CPBCHL
cp_bchl
CPDEV
cp_dev
CPKONS
cp_kons
CPNOANSW
cp_no_answ
CPNWCR
cp_nwcr
CPSBCRI
cp_sbcri
DHCONF
dh_conf
DHDEV
dh_dev
DHLINE
dh_line
DHLINK
dh_link
DHNWCR
dh_nwcr
DHSBCRI
dh_sbcri
DHSIU
dh_siu
Default value
:
all error classes
FAULT
Fault counter in table
Type of Input
:
Single value, optional
Possible Values
:
COUNT1
counter 1
COUNT2
counter 2
COUNT3
counter 3; only LEVEL=BOARD1 or BOARD2
COUNT4
counter 4; only LEVEL=BOARD1 or BOARD2
Meanings for levels BOARD and CIR:
COUNT1 Pairs counter
COUNT2 Flood of messages
Meanings for levels BOARD1 and BOARD2:
COUNT1 local alarms
COUNT2 remote alarms
COUNT3 AIS (Alarm Indication Signal)
COUNT4 automatic removal of module
Default value
:
all counters
LEVEL
Table level
Type of Input
:
Single value, mandatory
(CHANGE,TYPE=CTRLTAB/LOCKTIM/RESET/STABTIM;
DISPLAY,TYPE=COUNTER/CTRLTAB; REGENERATE,TYPE=CTRLTAB)
Single value, optional ( REGENERATE, TYPE=LOCKTIM/ STABTIM)
Possible Values
:
BOARD
Module level
BOARD1
Module level 1
BOARD2
Module level 2
CIR
Circuit level
DEV
Device level
LTUC
LTUC-level
For CHANGE/REGENERATE, TYPE=CTRLTAB only BOARD and CIR are permissible.
For CHANGE, TYPE=RESET, only BOARD1 and BOARD2 are permissible.
For DISPLAY, TYPE=COUNTER and CTRLTAB only BOARD, BOARD1, BOARD2 and CIR are permissible.
For CHANGE/REGENERATE, TYPE=LOCKTIM and STABTIM, BOARD, CIR, DEV und LTUC are permissible.
LINE
Line Type for Determination of Class of Table
Type of Input
:
Single value, mandatory (CHANGE, TYPE=CTRLTAB, LEVEL=CIR)
Single value, optional
(DISPLAY/ REGENERATE, TYPE=CTRLTAB, LEVEL=CIR)
Possible Values
:
CDG
cdg
DIUC
diuc
DIUC64
diuc64
DIUN2
diun2
DIUN4
diun4
DIUS2
dius2
NCUI
ncui
OTHER
all other
SLMB16
slmb16
SLMC
slmc
SLMO
slmo
SLMQ
slmq
SLMS
slms, slms2, stmd2 (q2163-x100)
SLMU16
slmu16
SLMY
slmy
STHC0
sthc (sircuit 0-15)
STHC16
sthc (circuit 16-19)
STMANW20
stma networking 2.0
STMANW21
stma networking 2.1
STMAPSW
stma port-switching
STMI
stmi
STMI2IGW
stmi2-igw (HG3550-2)
TMDNBOS
tmdn64 bos
TMDNMOS
tmdn64 mos
VCM
vcm
MAXCOUNT
Threshold of statistics counter
Type of Input
:
Single value,
optional (TYPE = CTRLTAB)
mandatory (TYPE = VECOLEVL)
Possible Values
:
0
Counter is deactivated
1 to 255
Threshold is n
(at TYPE = CTRLTAB only odd values permitted)
MODE
Operation mode of VECO
Type of Input
:
Single value, optional
Possible Values
:
ONWMSG
veco statistics with periodic statistics printout
ONWOMSG
veco statistics without periodic printout
STATOFF
VECO Statistics off
Default value
:
no change of mode
PEN
Pen of a module or of a circuit
Type of Input
:
3 single values, linked with -, mandatory
at LEVEL=BOARD, BOARD1 or BOARD2
:
4 single values, linked with -, mandatory
bei LEVEL=CIR
Possible Values
:
g-uu-sss for LEVEL = BOARD, BOARD1 or BOARD2
gg-u-sss-cc for LEVEL = CIR
g
= LTG 1 (no other value)
uu
= LTU 1 to 15 in HHS (Host Shelf)
16 not defined
17 to 99 in P (Access Point Shelf)
sss
= Slot 1 to 121
cc
= Circuit number 0 to 254
A suitable module must be configured to the slot addressed by PEN (AMO
BCSU
).
The possible LTU and Slot values for PEN depend on the systems architecture and can be found in the BCSU AMO description.
The possible Line values depend on the module type and its functionality.
They can be listed using DISP-
BCSU
: TYPE=PEN1 [,LTG=, LTU=, SLOT=, CCT=]; which will also output the actual PEN status (e.g. NOT CONNECTED).
PERIOD
Distance of periodic outputs (hours)
Type of Input
:
Single value, optional
Possible Values
:
1 - 65535
Default value
:
24
STIM
Stabilisation time
Type of Input
:
Single value, mandatory
Possible Values
:
10 - 30
SWITCH
State for single error class
Typ of Input:
:
Single value, mandatory
Possible Values
:
ON
Threshold signalling on
OFF
Threshold signalling off
TIME
Size of time interval as multiple of Basic time (currently 60 seconds)
Type of Input
:
Single value, optional
Possible Values
:
1 to 65535
TIM1...TIM 8
Lock time 1...8
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 (TIM1)
0 - 60 (TIM2 - TIM8)
The Parameters TIM1...TIM8 form a group. At least 1 parameter is to be entered.
TYPE
Branch Parameter
Type of Input
:
Single value, optional (REGENERATE)
Single value, mandatory (other branches)
Possible Values
:
CTRLTAB, RESET, VECOGEN, VECOLEVL, VECOSWCH, LOCKTIM, STABTIM (CHANGE)
COUNTER ,CTRLTAB, VECO, LOCKTIM, STABTIM (DISPLAY)
CTRLTAB, VECO, LOCKTIM, STABTIM, ALL (REGENERATE)
Default value
:
ALL
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.