154.6.4
Appendix 2, Part 4: Initblocks 61 till 80
THERE ARE NOT PTIME-BLOCKS (61-65)
(66): DB_AM_DEV_QSEMUSW : TSEMUSW
Longtimer
Default
(ms)
Description
Remark
L1
600
Guard time for release after preemption
(600- 5800 ms)
L2
326
Minimum time for recognition of 345ms valid pulse
(315- 375 ms)
L3
345
Time for preemption transmission 345ms pulse
(300- 390 ms)
L4
0
reserve
L5
0
reserve
L6
0
reserve
L7
0
reserve
Shorttimer
Default
(ms)
Description
Remark
S1
34
Total tolerance time (+/-17ms) for recogniton of pulse
(8- 60 ms)
S2
81
Minimum time for recognition of 100ms valid pulse
(70- 130 ms)
S3
100
Time for preemption transmission 100ms pulse
(70- 130 ms)
S4
0
reserve
S5
0
reserve
S6
0
reserve
S7
0
reserve
S8
0
reserve
S9
0
reserve
S10
0
reserve
S11
0
reserve
S12
0
reserve
S13
0
reserve
S14
0
reserve
Parameter
Default
Description
Remark
P1
0
Trunk used as MLPP trunk
0
Not used as MLPP trunk
1
Used as MLPP trunk
P2
0
reserve
P3
0
reserve
P4
0
reserve
P5
0
reserve
P6
0
reserve
P7
0
reserve
P8
0
reserve
P9
0
reserve
P10
0
reserve
P11
0
reserve
P12
0
reserve
P13
0
reserve
P14
0
reserve
The circuit type:
(67): DB_AM_DEV_QSEMAL_W2 : QSEMAL2 : TSEMU2
(68): DB_AM_DEV_QSEML1_W2 : QSEML12 : TSEML12
(69): DB_AM_DEV_QSEMSCH_W2 : QSEMSCH2 : TSEML2
are not longer allowed to use, they will substitute with QSEMCONT : TSEMCONT
at the module TMEW2 Q2292-X
100
The circuit type:
(70): DB_AM_DEV_QSEMID_W2 : QSEMID2 : TSEMI2
(71): DB_AM_DEV_QSEMDD_W2 : QSEMDD2 : TSEMD2
(72): DB_AM_DEV_QSEMUSD_W2 : QSEMUSD2 : TSEMUSD2
(73): DB_AM_DEV_QSEMUSI_W2 : QSEMUSI2 : TSEMUSI2
(74): DB_AM_DEV_QSEMUSW_W2 : QSEMUSW2: TSEMUSW2
(75): DB_AM_DEV_SOCOTFR_W2 : SOCOTFR2 : SOCFR2
are not longer allowed to use, they will substitute with EMCONT2
at the module TMEW2 Q2292-X
100
The circuit type:
(76): DB_AM_DEV_QSFT_W2 : QSTF2 : TSC2
is not longer allowed to use, it will substitute with QSTF3 : TF3
at the module TMEW2 Q2292-X
100
(77): DB_AM_DEV_EMCONT: EMCONT
Longtimer
Default
(ms)
Description
Remark
L1
5000
maximum recognition time for seizure acknowledge pulse
(40-10000 ms)
L2
180
maximum recognition time for release guard
(40- 500 ms)
L3
120
minimum recognition time for clear forward or release backward
(0-600 ms)
L4
85
transmission time of release guard
(40- 500 ms)
L5
100
minimum recognition time for seizure
(0- 500 ms)
L6
200
minimum recognition time for release acknowledge
(0- 1000 ms)
L7
400
minimum transmission time for answer
(0- 1000 ms)
Shorttimer
Default
(ms)
Description
Remark
S1
80
min. recognition time for seizure acknowledge pulse
(40- 200 ms)
S2
100
min. transmission time for clear backward before release guard
(0- 255 ms)
S3
30
supervision time for glare seizure
0 2.4 s
1 - 255 time in ms
S4
140
transmission time for wink start
0 300ms
60 - 255 time in ms
S5
100
minimum transmission time for delay dial
(0- 255 ms)
S6
60
minimum recognition time for metering pulse
(20 - 255 ms)
S7
0
alarm recognition (only for Q2092-X200)
0 without alarm recognition
1 with alarm recognition
S8
28
number of override impulses
(0-50)
S9
0
allowed time for override impulse
0 without override
1 override without time limit (valid after eod_busy,
eod_free and before end-of-dial)
2-60 s time in sec.
S10
0
supervision time for ready line signal (seizure ackn.)
(0-6s)
0 no supervision of ready signal
1-6 time in sec
S11
0
supervision time for clearback line signal
(0-6s)
0 no supervision of ready clearback signal
1-6 time in sec
S12
1 s
retry timer for active phase of test procedure - time in sec.
(1-10 s)
S13
60 s
retry timer for passive phase of test procedure - time in sec.
(1- 255 s)
S14
1 s
supervision time for clear forward (blocking or alarm recognition
0 no supervision of blocking
1- 255 supervision in sec
Parameter
Default
Description
Remark
P1
0
seizure acknowledge
0
immediate dial
1
delay dial
2
Wink Start
3
continuous signal
P2
0
test procedure
0
no test procedure
1
with test procedure
P3
0
signalling direction
0
bothway directed (glare seizure: priority of incoming seizure)
1
outgoing directed
2
incoming directed
3
bothway directed (glare seizure: release of line)
P4
0
conversation supervision
0
endless (no supervision)
1-255
multiplied with 30 sec.
P5
1
guard time before new outgoing seizure in seconds
0
500 msec
1-255
multiplied with 1 sec.
P6
0
dial tone recognition
0
no dial tone recognition
1
dial tone recognition
P7
120
answer supervision in case of outgoing directed traffic
0
no answer supervision
1-255
answer supervision in seconds
P8
1
blocking as line signal, if bothway or incoming directed traffic
0
without blocking as line signal
1
with blocking as line signal
P9
0
metering pulse recognition
0
no metering pulse recognition
1
metering pulse recogniton
P10
0
release guard as line signal
0
without release guard as line signal
1
with release guard as line signal
P11
1
answer as line signal
0
without answer as line signal
1
with answer as line signal
P12
0
dialing method
0
without digit pulsed
1
digit pulsed
P13
2
special clear backward with pseudo-answer and backward release on incoming side before answer
0
not used
1
after called subscriber busy
2
after release from DH
3
after called subscriber busy or release from DH
P14
0
inverse signaling
0
normal signalling
(idle state : M=OFF / E=OFF)
1
inverse signalling
(idle state : M=ON / E=ON)
2
inverse signalling only on E-wire
(idle state : M=OFF / E=ON)
3
inverse signalling only on M-wire
(idle state : M=ON / E=OFF)
(78): DB_AM_DEV_EMDISC: EMDISC
Longtimer
Default
(ms)
Description
Remark
L1
5000
supervision time for start dial signal after seizure on outgoing traffic
(40-10000 ms)
out
L2
625
transmission time for long impulse on outgoing traffic
(200- 2000 ms)
out
L3
300
transmission time for long pause on incoming traffic
(clear back pulse train)
(100-1000 ms)
in
L4
270
minimum recognition time for long impulse on
incoming traffic
(S3 + S4 + L4)
(100-1000 ms)
in
L5
2000
maximum recognition time for long impulse on incoming traffic
(L5 > S3 + S4 + L4)
(4000- 5000 ms)
in
L6
400
recognition time for long pause on outgoing traffic
(clear back pulse train)
(50- 1000 ms)
out
L7
0
reserve
Shorttimer
Default
(ms)
Description
Remark
S1
100
transmission time for short impulse on incoming and outgoing traffic
(40- 250ms)
out
S2
100
transmission time for short pause on incoming traffic
(0- 255 ms)
in
S3
70
minimum recognition time for short impulse on incoming and outgoing traffic
(40- 250 ms)
in/out
S4
60
maximum recognition time for short impulse on incoming and outgoing traffic
(S3 + S4)
(20- 250 ms)
in/out
S5
150
recognition time for short pause on outgoing traffic
(EOD_free, EOD_busy)
(20- 250 ms)
out
S6
50
supervision time for glare seizure on outgoing traffic
(20- 255 ms)
in
S7
0
reserve
S8
0
reserve
S9
0
reserve
S10
0
reserve
S11
0
reserve
S12
0
reserve
S13
0
reserve
S14
0
reserve
Parameter
Default
Description
Remark
P1
0
start dial line signal
out
0
no start dial line signal
1
with start dial line signal
P2
0
restore procedure, if bothway or outgoing directed traffic
out
0
no restore procedure
1
with restore procedure (put in service)
2
with restore procedure (line alarm)
3
with restore procedure
(in service and line alarm)
P3
0
signalling direction
in/out
0
bothway directed (glare seizure: priority of incoming seizure)
1
outgoing directed
2
incoming directed
3
bothway directed (glare seizure: release of line)
P4
0
end-of-dial line signal
in/out
0
no End-of-dial line signal
1
with End-of-dial line signal
(EOD_free and EOD_busy)
P5
1
guard time before new outgoing seizure in seconds
in/out
0
500 msec
1-255
multiplied with 1 sec.
P6
0
dial tone recognition
out
0
no dial tone recognition
1
dial tone recognition
P7
0
answer supervision in case of outgoing directed traffic
out
0
no answer supervision
1-255
answer supervision in seconds
P8
0
blocking as line signal, if bothway or incoming directed traffic
in
0
without blocking as line signal
1
with blocking as line signal
P9
0
forward release after EOD-busy
(valid only when P4=1)
out
0
without forward release
1
with forward release
P10
0
reserve
P11
0
reserve
P12
0
dialing method
in/out
0
MF-Dial (multifrequency)
1
DP-Dial (dial pulse)
P13
5
reanswer supervision time on outgoing traffic
out
0
immediate forward release to the line after clear back
1-254
delayed forward release to the line after clear back (... x 1s)
255
endless (no forward release to the line after clear back, waiting for release from DH)
P14
40
supervision time for release forward after clear back on incoming traffic
in
0
endless forward release supervision
1-255
alarm to DH after supervision time (... x 1s)
(79): DB_AM_DEV_TMLRUD: TMLRUD
Longtimer
Default
(ms)
Description
Remark
L1
700
release gap to tie (outgoing)
(300- 1000 ms)
L2
150
release gap minimum from tie (incoming)
(50- 300 ms)
L3
1000
blocking against new seizure
(500- 5000 ms)
L4
120
time between reversals by start of dial in time
(100- 300 ms)
L5
4000
time for recognition of line alarm by line supervision
(2000- 6000 ms)
L6
4000
waiting time for release acknowledge from tie (incoming)
(2000- 6000 ms)
L7
0
reserve
Shorttimer
Default
(ms)
Description
Remark
S1
120
remote blocking pulse (outgoing)
(80-255 ms)
only if P1=1.
S2
40
minimal time for seizure recognition
(20- 40 ms)
only if P1=0 or P1=2.
(for P1=1 minimal time for seizure recognition is S7 + S8)
S3
60
minimal time after outgoing seizure untill current recognition (outgoing)
(40-100 ms)
only if P1=0.
(for P1=1 or 2: see S9)
S4
200
maximal time for start of dial in time (outgoing)
(100-250 ms)
S5
40
minimal time for recognition of a line interruption (incoming)
(10-80 ms)
S6
20
time between potential-recognition and acknowledge to DH (outgoing)
(10- 250 ms)
for P1=1 do S6=150m,
for P1=0 or P1=2 do
S6=20ms.
S7
110
remote blocking pulse minimum (incoming)
(80- 200 ms)
S8
40
remote blocking pulse tolerance (incoming)
(10- 60 ms)
S9
100
maximal time after outgoing seizure until current recognition (outgoing)
(50- 200 ms)
only if P1=1 or P1=2.
(for P1=0 see S3)
S10
20
dialing pulse minimum (incoming)
(10- 30 ms)
S11
20
dialing pause minimum (incoming)
(10- 30 ms)
S12
20
recogniton of a saved potential after line alarm (incoming)
(10- 50 ms)
S13
0
reserve
S14
130
interdigit time minimum (incoming)
(100- 200 ms)
Parameter
Default
Description
Remark
P1
0
operating mode
0
feeding with line supervision
1
feeding with remote blocking
2
loop without line supervision and remote blokkingrt
P2=1 only if P1=1
P2
0
send remote blocking (only valid if p1=1)
0
without blocking signal
1
with blocking signal
P3
0
start of dial signal
0
without start of dial signal
1
with start of dial signal in time (L4, S4)
P3=1 only if P1=0 or P1=1
2
with continuous start of dial signal
P3=2 only if P1=0 or P1=1
P4
2
end of dial and answer
0
without end of dial, without answer
1
with end of dial, without answer
P4=1 only if P1=0 or P1=1
2
without end of dial, with answer
P4=2 only if P1=0 or P1=1
3
with end of dial, with answer
P4=3 only if P1=0 or P1=1
P5
0
automatic end of dial signal (only valid if p1=0 or 1)
0
without
n
no. of digits till automatic end of dial
(n=1...20)
P5=1 only if P4=1 or P4=3
P6
0
seizure acknowledge
0
acknowledge with BEL_QUITTUNG
(a dialtone receiver will be connected, digits will be send from DH after a valid dialtone)
P6=0 only if P3=0
1
acknowledge with WAHLABRUF
(digits will be send from DH immediately)
P7
1
alarm in case of release supervision:
0
with alarm by release supervision (L6)
P7=0 only if P1=1 and P8=1
1
without alarm
2
ignore release from tie line
P7=2 only for test
P8
0
backward release transmission after answer
(incoming):
0
with feeding gap
P8=0 only if P1=0 or P1=1.
1
with reversal
P8=1 only if P1=0 or P1=1
P9
0
backward release recognition after answer
(outgoing):
0
ignore reversal after answer
P9=0 only if P1=0 or P1=1
1
interpret reversal after answer as release
P9=1 only if P1=0 or P1=1.
P10
0
change of level by message PEGEL_SCHALTEN:
0
no change of level
1
change of level possible
P11
0
reserve
P12
0
reserve
P13
0
reserve
P14
0
reserve
(80): DB_AM_DEV_DFADASE: DFADASE
Longtimer
Default
(ms)
Description
Remark
L1
300
max recognition time for answer
(300-3000 ms)
L2
0
reserve
L3
0
reserve
L4
0
reserve
L5
0
reserve
L6
0
reserve
L7
0
reserve
Shorttimer
Default
(ms)
Description
Remark
S1
100
verification of line signal end
(20-200 ms)
S2
0
reserve
S3
0
reserve
S4
0
reserve
S5
0
reserve
S6
0
reserve
S7
0
reserve
S8
0
send level for 2 VF fwd / bwd release signal
0 send level is equal 1 VF signals
1 send level is higher than 1VF signals
S9
0
send level for 2 VF out of service signal
0 send level is equal 1 VF signals
1 send level is higher than 1VF signals
if P4=3 or 4
S10
0
incoming seizures during line supervision alarm
if P12=1
0 no incoming seizure is accepted
1 - inc. dispatcher seizures accepted at once
- inc. normal seizures are not accepted
2 - inc. dispatcher seizures accepted at once
- inc. normal seizures accepted as 3rd f1 test
pulse
S11
0
LTG-alarm printout
0 only one LTG_ALARM type
HICOM version <V1.0
(ZEITUEBERLAUF_4 to DH)
1 different LTG_ALARM types
HICOM version >= V1.0
(SPERREN to DH)
S12
0
reserve
S13
0
reserve
S14
0
reserve
Parameter
Default
Description
Remark
P1
1
send level for VF signals
0
high =0 dBm0 (FW1) / low =-8,8 dBm0 (FW2)
1
standard=-4,4 dBm0 (FW1 + FW2)
P2
0
restriction of normal calls by dispatcher dialling
for time limit
refer to P9
0
no dailling by dispatcher possible
1
restrict normal calls by dispatcher dialling
digit to be dialed by dispatscher corresponds the value of P3
2
restrict normal calls by dispatcher dialling and
transmit digit to remote switch (only outgoing traffic)
P3
0
restriction of normal calls by initialisation
for time limit refer to P9
0
no restriction
1
restriction of
outgoing + incoming normal calls
2
restriction of outgoing normal calls
3
restriction of incoming normal calls
P4
0
blocking transmission
0
no blocking
1
blocking with 1200Hz
2
blocking with 1600Hz
3
blocking with 1200/1600Hz
4
alternating blocking cycles for line frequency test
for timing refer to P10/P11
P5
0
speech path through connection befor answer
0
one way through connection
1
both way through connection
P6
0
post dialling
0
no post dialling
1
post dialling
P7
4
answer supervision in outgoing traffic
0
no answer supervision
1-60
answer supervision time in 30 sec. steps
P8
0
change of level attenuation
0
no change of level attenuation
1
change of level attenuation possible
P9
12
time limit for restriction of normal calls
refer to P3
0
no time limit for restriction
1-255
time limit for restriction of normal calls in 10 min. steps
P10
4
transmission time of frequency in line test
only if P4=4
0
10s test tone on
1-100
transmission time
in multiples of 10s
P11
1
pause time between frequencies in line test
only if P4=4
0
10s test tone off
1-100
pause time in multiples of 10s
P12
0
line supervision in idle
0
no line supervision
1
with line supervision
P13
0
suppression of received line signals
0
during transmission received line signals are accepted
1
during transmission received line signals are suppressed
P14
4
answer supervision for incoming traffic
0
no answer supervision
1-60
answer supervision time
in multiples of 30s
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.