158.4
Parameter Description
APSVERSn
Version of software load to be generated
Type of Input
:
Single value, optional
Possible Values
:
APS Version, 17 chars.
ARCHIVE
Storage of end messages from DAGEN functions in the ADS
Type of Input
:
Single value, optional
Possible Values
:
No, Yes
Default Value
:
No
BSACCNO
Charge account number for BS2000
Type of Input
:
Single value, mandatory
Possible Values
:
Any valid BS2000 account number (max. 8 chars.)
BSLOGID
User ID for host with BS2000 operating system
Type of Input
:
Single value, mandatory
Possible Values
:
Any valid BS2000 user IDs
(max. 8 chars.)
BSPTNR
Symbolic name of BS2000 host in CMS format
Type of Input
:
Single value, mandatory
Possible Values
:
NETW name of connected BS2000 host
BSPWD
BS2000 password
Type of Input
:
Single value, mandatory
Possible Values
:
BS2000 password valid for user ID, entered’ in inverted commas with prefix "c" or "x"
(e.g. c’<password>’)
CFIGCUSn
REGEN options: configuration data / customer data / both
Type of Input
:
Single value, linked single values,
optional
Possible Values
:
CFIGDA, CUSTDA
Default Value
:
CFIGDA&CUSTDA
CONT
Continuation after iterrupt
Type of Input
:
Single value, mandatory
Possible Values
:
Y, N
Default Value
:
N
DATYPE
Data types other than static database
Type of Input
:
Single value, linked single values, optional
Possible Values
:
FLEX, MODSTA, PROJ, MDF, NONE, ALL
FLEX
= Flexible assigned memory
MODSTA
= Module status
PROJ
= Project planning data
MDF
= Main distribution frame
Default Value
:
NONE
DEL
Deletion of logfile (LOGEXE) and/or result file (MMLFILE) after successful file transfer in BS2000
Type of Input
:
Single value, linked single values, optional
Possible Values
:
LOGEXE, MMLFILE, NONE or ALL
FDAT
File to be transferred
Type of Input
:
Single value, linked single values, optional
Possible Values
:
LOGEXE, MMLFILE or ALL
Default Value
:
ALL
FTRNS
Transfer all LOGEXES and MMLFILES from ADS to BS2000 host
(on completion of REGEN run)
Type of Input
:
Single value, optional
Possible Values
:
Y, N
Default Value
:
N
MMLFILE
Name of file which contains the NOUNS of the regenerating AMOs
Type of Input
:
Single value, optional
Possible Values
:
Any filenames valid for the system up to 32 chars.
NOUN
Noun to be generated
Type of Input
:
Textstring, optional
Possible Values
:
all MML-Nouns, which can be linked with the verb REGENERATE; up to two NOUNs can be entered; must be separated with comma and entered in in inverted commas; max. 11 chars.
PROT
Output of listing at service terminal
Type of Input
:
Single value, optional
Possible Values
:
Y, N
Default Value
:
N
STANDBY
Regeneration on active or standby processor
Type of Input
:
Single value, optional
Possible Values
:
Y, N
Default Value
:
N
SYSNO
Number of customer system
Type of Input
:
Single value, optional
Possible Values
:
Any valid system numbers, max. 17 chars.
Default Value
:
Number of the loaded database
SYSTYPE
System type
Type of Input
:
Single value, optional
Possible Values
:
SUPPORT, CUST
Default Value
:
CUST
UNITn
Type of module to be regenerated, i.e. SWU or server
Type of Input
:
Single value, linked single values,
optional
Possible Values
:
SWU
switching unit
SWUKEY
switching unit with keywords
ADS
administration and data server
ADSKEY
administration and data server with keywords
NONE
none
ALL
all
ALLKEY
all with keyword
Default Value
:
ALL
USERCODE
User identity
Type of Input
:
Single value, mandatory
Possible Values
:
Any desired text string, max. 7 chars.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.