160.3.3
DISPLAY-REST
Displays:
1.
whether rescue software is used,
2.
output the state of a functional unit.
•
If the SWU unit (CC, LTG or CSN) is entered in the input command, the unit’s dependability state (FA or ’fault analysis’ state) is queried.
•
If the parameter UNIT is not entered in the input command, the output will contain the dependability state (FA or ’fault analysis’ state) of all functional units.
Procedure Overview
Command Code
Parameter
DISPLAY-REST
[UNIT=<param>];
Examples
1.
Display the fault analysis state of SWU units
Input:
DISPLAY-REST:BPB&GP1A&GP1B&GP7A&GP7B;
Output:
+------------------+------+
| USE RESCUE SW | NO |
+------------------+------+
+------------------+--------------------------+
| FUNCTIONAL UNIT | FAULT ANALYSIS STATUS |
+------------------+--------------------------+
| BPB | INACTIVE |
| GP1A | STANDBY |
| GP1B | ACTIVE |
| GP7A | NOT_AVAILABLE |
| GP7B | NOT_AVAILABLE |
+------------------+--------------------------+
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.