162.3.3
DISPLAY-RUFUM
If no station numbers are specified, only the TYPE, all entries with the requested TYPE are output.
In the branch TYPE=STNO2, all station numbers are output which will be converted to the specified station number. If TYPE is not specified, all entries are output.
Procedure Overview
Command Code
Parameter
DISPLAY-RUFUM
[TYPE=DID],[DID1=<=<number>];
|[TYPE=COMB],[FAX1=<number>],[DTE1=<number>];
|[TYPE=STNO2],STNO2=<number>;
Example
Input:
DIS-RUFUM:TYPE=COMB;
Output:
+-----------+-----------------+-------------+
| TYPE | DIALLED CODE | CONV. CODE |
+-----------+-----------------+-------------+
| COMB-FAX | 60 | 2110 |
| COMB-FAX | 61 | 2111 |
| COMB-FAX | 64 | 2112 |
| COMB-FAX | 65 | 2113 |
| COMB-FAX | 62 - 63 | 2114 |
+-----------+-----------------+-------------+
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5