167.3.1
ADD-SCREN
This action can:
•
assign up to 200 screening patterns (max. 10/command) to a screening pattern plan,
•
assign the screening data and/or the screening pattern plan to a source node number.
After performing the data for a source node number an advisory message is displayed.
First the screening patterns must be assigned to a plan which then can be assigned to one or more source node numbers. If a not existing plan is entered, when configuring the screening data, the plan will be ignored.
If no screening pattern plan SCRPPLAN but the type of plan SCRPTON is entered, the SCRPTON will be ignored.
If no default number operator DNO but the type of default number operator DNOTON is entered, the DNOTON will be ignored.
Procedure overview
Commandcode
Parameter
ADD-SCREN
TYPE=SCRPATT, SCRPPLAN=<number>, SCRP=<string>;
| TYPE=SCRDATA, SNNO=<number>, [DNO=<key-num>],
[DNOTON=<param>], [TOSCAL=<param>],[PRESCAL=<param>],
[TOSCOL=<param>], [PRESCOL=<param>],
[SCRPPLAN=<number>], [SCRPTON=<param>],
[LOCDEST=<key-num>];
Examples
1.
Assign five valid screening patterns to screening pattern plan 35
Input:
ADD-SCREN:TYPE=SCRPATT,SCRPPLAN=35,
SCRP=00994873&337467883934000&783*7784X&987564566677XX#&899898990004455#;
2.
Assign some screening data (DNO, DNOTON, TOSCOL, SCRPPLAN, SCRPTON) to source node number 12-343
Input:
ADD-SCREN:TYPE=SCRDATA,SNNO=12-343,DNO=0099487*6778,DNOTON=UNKNOW,TOSCOL=SCREEN,
SCRPPLAN=35,SCRPTON=INTERNAT;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5